GaAs pixel radiation detector as an autoradiography tool for genetic studies

被引:14
作者
Bertolucci, E
Conti, M [1 ]
Mettivier, G
Russo, P
Amendolia, SR
Bisogni, MG
Bottigli, U
Ceccopieri, A
Ciocci, MA
Delogu, P
Fantacci, ME
Maestro, P
Marzulli, VM
Pernigotti, E
Romeo, N
Rosso, V
Stefanini, A
Stumbo, S
机构
[1] Univ Naples Federico II, Dept Phys, Naples, Italy
[2] Ist Nazl Fis Nucl, I-80125 Naples, Italy
[3] Univ Pisa, Dept Phys, I-56100 Pisa, Italy
[4] Ist Nazl Fis Nucl, Pisa, Italy
关键词
autoradiography; genetics; GaAs;
D O I
10.1016/S0168-9002(98)01102-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present an autoradiography tool to be used mainly for genetic studies. It performs a quantitative analysis of radioactivity and can follow a dynamic process. We designed several applications, in particular one aimed at detecting hybridization of radio-labeled DNA fragments with known DNA-probes deposited on a micro-array. The technique is based on GaAs pixel array detector and low threshold, large dynamic range and good sensitivity integrated electronics developed for medical applications, suitable to detect markers (gamma or beta) such as C-14, S-35, P-33, P-32, I-125, even at very low activities. A Monte Carlo simulation of beta(-) detection in GaAs is presented here in order to study the spatial resolution characteristics of such a system. For several biological applications, the electronics is required to perform at high temperatures (from 37 degrees to 68 degrees): we present here studies of noise and minimum threshold as a function of the temperature. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:242 / 246
页数:5
相关论文
共 4 条
[1]   MEDIPIX: a VLSI chip for a GaAs pixel detector for digital radiology [J].
Amendolia, SR ;
Bertolucci, E ;
Bisogni, MG ;
Bottigli, U ;
Ceccopieri, A ;
Ciocci, MA ;
Conti, M ;
Delogu, P ;
Fantacci, ME ;
Maestro, P ;
Marzulli, V ;
Pernigotti, E ;
Romeo, N ;
Rosso, V ;
Rosso, P ;
Stefanini, A ;
Stumbo, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :201-205
[2]   Use of silicon and GaAs pixel detectors for digital autoradiography [J].
Amendolia, SR ;
Beccherle, R ;
Bertolucci, E ;
Bisogni, MG ;
Bottigli, U ;
Campbell, M ;
Chesi, E ;
Ciocci, MA ;
Conti, M ;
DaVia, C ;
DelGuerra, A ;
DAuria, S ;
Fantacci, ME ;
Gambaccini, M ;
Grossi, G ;
Heijne, E ;
Mancini, E ;
Marchesini, R ;
Middelkamp, P ;
OShea, V ;
Randaccio, P ;
Romeo, N ;
Rosso, V ;
Russo, P ;
Scharfetter, L ;
Smith, K ;
Snoeys, W ;
Stefanini, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :929-933
[3]   Autoradiography with silicon strip detectors [J].
Bertolucci, E ;
Conti, M ;
Grossi, G ;
Madonna, G ;
Mancini, E ;
Russo, P ;
Caria, M ;
Randaccio, P ;
delGuerra, A ;
Gambaccini, M ;
Marchesini, R ;
Marziani, M ;
Taibi, A ;
Beccherle, R ;
Bisogni, MG ;
Bottigli, U ;
Fantacci, ME ;
Rosso, V ;
Stefanini, A ;
Tripiccione, R ;
Amendolia, SR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (2-3) :527-530
[4]   Extensive polymorphisms observed in HIV-1 clade B protease gene using high-density oligonucleotide arrays [J].
Kozal, MJ ;
Shah, N ;
Shen, NP ;
Yang, R ;
Fucini, R ;
Merigan, TC ;
Richman, DD ;
Morris, D ;
Hubbell, ER ;
Chee, M ;
Gingeras, TR .
NATURE MEDICINE, 1996, 2 (07) :753-759