Use of silicon and GaAs pixel detectors for digital autoradiography

被引:15
作者
Amendolia, SR
Beccherle, R
Bertolucci, E
Bisogni, MG
Bottigli, U
Campbell, M
Chesi, E
Ciocci, MA
Conti, M
DaVia, C
DelGuerra, A
DAuria, S
Fantacci, ME
Gambaccini, M
Grossi, G
Heijne, E
Mancini, E
Marchesini, R
Middelkamp, P
OShea, V
Randaccio, P
Romeo, N
Rosso, V
Russo, P
Scharfetter, L
Smith, K
Snoeys, W
Stefanini, A
机构
[1] IST NAZL FIS NUCL,PISA,ITALY
[2] UNIV PADUA,DIPARTIMENTO FIS,PADUA,ITALY
[3] IST NAZL FIS NUCL,PADUA,ITALY
[4] UNIV NAPLES FEDERICO II,DIPARTIMENTO SCI FIS,NAPLES,ITALY
[5] IST NAZL FIS NUCL,I-80125 NAPLES,ITALY
[6] UNIV PISA,DIPARTIMENTO FIS,PISA,ITALY
[7] IST NAZL FIS NUCL,PISA,ITALY
[8] CERN,GENEVA,SWITZERLAND
[9] UNIV GLASGOW,GLASGOW,LANARK,SCOTLAND
[10] UNIV FERRARA,DIPARTMENTO FIS,I-44100 FERRARA,ITALY
[11] IST NAZL FIS NUCL,FERRARA,ITALY
[12] UNIV CAGLIARI,IST FIS MED,CAGLIARI,ITALY
[13] IST NAZL FIS NUCL,CAGLIARI,ITALY
关键词
D O I
10.1109/23.603779
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Solid state detectors made of Si (4.8x8 mm(2)) and GaAs (6.4x8 mm(2)) pixel matrices bump-bonded to the Omega2 and Omega3 electronic read-out systems, developed at CERN for H.E.P. experiments, have been used to obtain autoradiographic images of clusters of human epithelial cells and DNA fragments separated via electrophoresis, both labeled with P-32. The system has shown a good minimum detectable activity per unit area of 2. 10(-4) cps mm(-2), and has proved linear for count rate in the range 0.2-20 cpa, typical of autoradiography. The pixel dimensions are 75x500 mu m(2) (Si-Omega2) and 50x500 mu m(2)(GaAs-Omega3), respectively. We are able to clearly localize clusters of cells which have incorporated the radioactive tracer and DNA fragments on an electrophoretic gel on paper (blots).
引用
收藏
页码:929 / 933
页数:5
相关论文
共 3 条
[1]   Autoradiography with silicon strip detectors [J].
Bertolucci, E ;
Conti, M ;
Grossi, G ;
Madonna, G ;
Mancini, E ;
Russo, P ;
Caria, M ;
Randaccio, P ;
delGuerra, A ;
Gambaccini, M ;
Marchesini, R ;
Marziani, M ;
Taibi, A ;
Beccherle, R ;
Bisogni, MG ;
Bottigli, U ;
Fantacci, ME ;
Rosso, V ;
Stefanini, A ;
Tripiccione, R ;
Amendolia, SR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (2-3) :527-530
[2]   INFLUENCE OF ELECTRON TRAPS ON CHARGE-COLLECTION EFFICIENCY IN GAAS RADIATION DETECTORS [J].
NAVA, F ;
CANALI, C ;
CASTALDINI, A ;
CAVALLINI, A ;
DAURIA, S ;
DELPAPA, C ;
FRIGERI, C ;
ZANOTTI, L ;
CETRONIO, A ;
LANZIERI, C ;
ZICHICHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01) :156-159
[3]  
HEIJNE EHM, UNPUB NUCL INSTR M A