Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses

被引:153
作者
Smulyan, H
Siddiqui, DS
Carlson, RJ
London, GM
Safar, ME
机构
[1] SUNY Syracuse, Upstate Med Univ, Dept Med, Syracuse, NY 13210 USA
[2] Ctr Hosp, FH Manhes, Fleury Merogis, France
[3] Hop Broussais, Dept Internal Med, Paris, France
关键词
aorta; arterial pressure; Fourier analysis; blood pressure determination;
D O I
10.1161/01.HYP.0000084051.34269.A9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Brachial artery cuff blood pressures are but approximations of central aortic pressures. The actual pressures against which the left ventricle must pump would be useful clinical information if obtained noninvasively. Our aim was to determine the clinical utility of aortic pulses and pressures calculated from noninvasively obtained radial-artery pulses. Radial-arterial pulses were recorded by applanation and calibrated with arm/cuff oscillometric pressures. Aortic pulses and pressures were calculated from the radial pulses by Fourier analysis and transfer functions. These calculated aortic pulses were compared with directly recorded aortic pulses by a transducer-tip catheter in a series of 50 patients undergoing cardiac catheterization. The correlation coefficient (r) of the measured versus the calculated aortic systolic blood pressure was + 0.89, but the scatter was large ( standard deviation of the differences = +/- 11.3 mm Hg). The pulse pressure correlations were less good ( r = + 0.79) and also had a large scatter ( +/- 13.6 mm Hg). The average calculated pulse pressure was 11.5 mm Hg lower than the measured value because the cuff diastolic blood pressures, used to calibrate the radial pulses, were systematically higher than those in the aorta ( 8.9 mm Hg). Multivariable analysis incorporating height, age, heart rate, and ejection fraction as additional, independent variables eliminated mean differences between the new "predicted" and measured pressures, significantly improved correlation coefficients, and reduced the scatter. However, the improvements were small. The inaccuracy of the oscillometric cuff method for measuring arm blood pressure appears to be the limiting factor in the prediction of clinically useful, noninvasive aortic pressures.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 24 条
  • [1] American National Standard for Electronic or Automated Sphygmomanometers, 1993, ANSI AAMI SP, P12
  • [2] [Anonymous], 1976, PROGR REP
  • [3] NON-INVASIVE ESTIMATION OF CENTRAL AORTIC PRESSURE USING THE OSCILLOMETRIC METHOD FOR ANALYZING SYSTEMIC ARTERY PULSATILE BLOOD-FLOW - COMPARATIVE-STUDY OF INDIRECT SYSTOLIC, DIASTOLIC, AND MEAN BRACHIAL-ARTERY PRESSURE WITH SIMULTANEOUS DIRECT ASCENDING AORTIC PRESSURE MEASUREMENTS
    BOROW, KM
    NEWBURGER, JW
    [J]. AMERICAN HEART JOURNAL, 1982, 103 (05) : 879 - 886
  • [4] Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    Bur, A
    Hirschl, MM
    Herkner, H
    Oschatz, E
    Kofler, J
    Woisetschläger, C
    Laggner, AN
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (02) : 371 - 376
  • [5] Chen CH, 1997, CIRCULATION, V95, P1827
  • [6] BLOOD PRESSURE MEASUREMENT IN SHOCK - MECHANISM OF INACCURACY IN AUSCULTATORY AND PALPATORY METHODS
    COHN, JN
    [J]. JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 199 (13): : 972 - &
  • [7] Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure
    Davies, JI
    Band, MM
    Pringle, S
    Ogston, S
    Struthers, AD
    [J]. JOURNAL OF HYPERTENSION, 2003, 21 (03) : 571 - 576
  • [8] Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry
    Fetics, B
    Nevo, E
    Chen, CH
    Kass, DA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) : 698 - 706
  • [9] SPONTANEOUS DIAMETER OSCILLATIONS OF THE RADIAL ARTERY IN HUMANS
    HAYOZ, D
    TARDY, Y
    RUTSCHMANN, B
    MIGNOT, JP
    ACHAKRI, H
    FEIHL, F
    MEISTER, JJ
    WAEBER, B
    BRUNNER, HR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06): : H2080 - H2084
  • [10] Validation of the Welch Allyn 'Vital Signs' oscillometric blood pressure monitor
    Jones, CR
    Taylor, K
    Poston, L
    Shennan, AH
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2001, 15 (03) : 191 - 195