Radiographic comparison of pegged and keeled glenoid components

被引:78
作者
Gartsman, GM
Elkousy, HA
Warnock, KM
Edwards, TB
O'Connor, DP
机构
[1] Texas Orthoped Hosp, Fondren Orthoped Grp LLP, Houston, TX 77030 USA
[2] Univ Texas, Sch Med, Dept Orthopaed Surg, Houston, TX USA
[3] Joe W King Orthoped Inst, Houston, TX USA
关键词
D O I
10.1016/j.jse.2004.09.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Glenoid loosening is one reason for failure of total shoulder arthroplasty. Several factors, including radiographic lucency, have been shown to be associated with glenoid loosening. The purpose of this study was to assess the correlation between glenoid design and immediate radiographic lucency in a prospective randomized clinical trial. Total shoulder arthroplasty was performed in 43 patients over a 2-year period. Twenty-three patients were randomized into the keel group and twenty patients into the pegged group. Postoperative radiographs obtained within 6 weeks of surgery were evaluated by 3 raters to determine glenoid lucency. On a scale from 0 (no lucency) to 5 (gross lucency and component loosening), the rate of lucency was 39 % (9/23) in the keeled components, which was significantly higher than the rate of 5 % (1/20) observed in the pegged components (P = .026). Patient age, gender, and glenoid size did not significantly affect glenoid component lucency (P > .05). The consistency reliability among raters (Cronboch alpha) was 0.87, and the intertester reliability was 0.87. Pegged glenoid components have less radiographic lucency when compared with keeled glenoid components in the immediate postoperative period.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 33 条
[1]
CEMENTED TOTAL HIP-PROSTHESIS - RADIOGRAPHIC AND SCINTIGRAPHIC EVALUATION [J].
ALIABADI, P ;
TUMEH, SS ;
WEISSMAN, BN ;
MCNEIL, BJ .
RADIOLOGY, 1989, 173 (01) :203-206
[2]
EVALUATION OF A NONCONSTRAINED TOTAL SHOULDER PROSTHESIS [J].
ALIABADI, P ;
WEISSMAN, BN ;
THORNHILL, T ;
NIKPOOR, N ;
SOSMAN, JL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (06) :1169-1172
[3]
THE DANA TOTAL SHOULDER ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
KABO, JM ;
JINNAH, RH ;
DOREY, FJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1174-1282
[4]
[Anonymous], 1999, SHOULDER ARTHROPLAST
[5]
Does keel size, the use of screws, and the use of bone cement affect fixation of a metal glenoid implant? [J].
Bicknell, RT ;
Liew, ASL ;
Danter, MR ;
Patterson, SD ;
King, GJW ;
Chess, DG ;
Johnson, JA .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (03) :268-275
[6]
Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty:: A prospective, double-blind, randomized study [J].
Boileau, P ;
Avidor, C ;
Krishnan, SG ;
Walch, G ;
Kempf, JF ;
Molé, D .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (04) :351-359
[8]
Franklin J L, 1988, J Arthroplasty, V3, P39, DOI 10.1016/S0883-5403(88)80051-2
[9]
Retrieved glenoid components - A classification system for surface damage analysis [J].
Gunther, SB ;
Graham, J ;
Norris, TR ;
Ries, MD ;
Pruitt, L .
JOURNAL OF ARTHROPLASTY, 2002, 17 (01) :95-100
[10]
Characteristics of unsatisfactory shoulder arthroplasties [J].
Hasan, SS ;
Leith, JM ;
Campbell, B ;
Kapil, R ;
Smith, KL ;
Matsen, FA .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (05) :431-441