Functional assessment of the kidney from magnetic resonance and computed tomography renography: Impulse retention approach to a multicompartment model

被引:60
作者
Zhang, Jeff L. [1 ]
Rusinek, Henry [1 ]
Bokacheva, Louisa [1 ]
Lerman, Lilach O. [2 ]
Chen, Qun [1 ]
Prince, Chekema [1 ]
Oesingmann, Niels [3 ]
Song, Ting [1 ,4 ]
Lee, Vivian S. [1 ]
机构
[1] NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
[2] Mayo Clin, Coll Med, Div Nephrol & Hypertens, Rochester, MN USA
[3] Siemens Med Solut, Malvern, PA USA
[4] Columbia Univ, Dept Biomed Engn, New York, NY USA
关键词
computed tomography; glomerular filtration rate; impulse retention function; magnetic resonance renography; renal plasma flow;
D O I
10.1002/mrm.21489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-compartment model is proposed for analyzing magnetic resonance renography (MRR) and computed tomography renography (CTR) data to derive clinically useful parameters such as glomerular filtration rate (GFR) and renal plasma flow (RPF). The model fits the convolution of the measured input and the predefined impulse retention functions to the measured tissue curves. A MRR study of 10 patients showed that relative root mean square errors by the model were significantly lower than errors for a previously reported three-compartmental model (11.6%+/- 4.9 vs 15.5%+/- 4.1; P < 0.001). GFR estimates correlated well with reference values by Tc-99m-DTPA scintigraphy (correlation coefficient r = 0.82), and for RPF, r = 0.80. Parameter-sensitivity analysis and Monte Carlo simulation indicated that model parameters could be reliably identified. When the model was applied to CTR in five pigs, expected increases in RPF and GFR due to acetylcholine were detected with greater consistency than with the previous model. These results support the reliability and validity of the new model in computing GFR, RPF, and renal mean transit times from MR and CT data.
引用
收藏
页码:278 / 288
页数:11
相关论文
共 35 条
[1]   A pathophysiologic study of the kidney tubule to optimize organ preservation solutions [J].
Ahmad, N ;
Hostert, L ;
Pratt, JR ;
Billar, KJ ;
Potts, DJ ;
Lodge, JPA .
KIDNEY INTERNATIONAL, 2004, 66 (01) :77-90
[2]   Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[3]   TERMINOLOGY FOR MASS-TRANSPORT AND EXCHANGE [J].
BASSINGTHWAIGHTE, JB ;
CHINARD, FP ;
CRONE, C ;
GORESKY, CA ;
LASSEN, NA ;
RENEMAN, RS ;
ZIERLER, KL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (04) :H539-H545
[4]   Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI [J].
Baumann, D ;
Rudin, M .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :587-595
[5]   Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies [J].
Bokacheva, Louisa ;
Rusinek, Henry ;
Chen, Qun ;
Oesingmann, Niels ;
Prince, Chekema ;
Kaur, Manmeen ;
Kramer, Elissa ;
Lee, Vivian S. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1012-1018
[6]   Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects [J].
Buckley, David L. ;
Shurrab, Ala'a E. ;
Cheung, Ching M. ;
Jones, Andrew P. ;
Mamtora, Hari ;
Kalra, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1117-1123
[7]  
CHAIWATANARAT T, 1994, J NUCL MED, V35, P1792
[8]   Assessment of renal hemodynamics and function in pigs with 64-section multidetector CT: Comparison with electron-beam CT [J].
Daghini, Elena ;
Primak, Andrew N. ;
Chade, Alejandro R. ;
Krier, James D. ;
Zhu, Xiang-Yang ;
Ritman, Erik L. ;
McCollough, Cynthia H. ;
Lerman, Lilach O. .
RADIOLOGY, 2007, 243 (02) :405-412
[9]   AN ANATOMICAL AND PHYSIOLOGICAL MODEL OF THE RENAL PARENCHYMA - MODEL DEVELOPMENT AND PARAMETRIC IDENTIFICATION [J].
FINE, DR ;
LURIE, RE ;
CANDY, GP .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 (04) :407-428
[10]   Three-dimensional microcomputed tomography of renal vasculature in rats [J].
Garcia-Sanz, A ;
Rodriguez-Barbero, A ;
Bentley, MD ;
Ritman, EL ;
Romero, JC .
HYPERTENSION, 1998, 31 (01) :440-444