Functional assessment of the kidney from magnetic resonance and computed tomography renography: Impulse retention approach to a multicompartment model
被引:60
作者:
Zhang, Jeff L.
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Zhang, Jeff L.
[1
]
Rusinek, Henry
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Rusinek, Henry
[1
]
Bokacheva, Louisa
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Bokacheva, Louisa
[1
]
Lerman, Lilach O.
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin, Coll Med, Div Nephrol & Hypertens, Rochester, MN USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Lerman, Lilach O.
[2
]
Chen, Qun
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Chen, Qun
[1
]
Prince, Chekema
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Prince, Chekema
[1
]
Oesingmann, Niels
论文数: 0引用数: 0
h-index: 0
机构:
Siemens Med Solut, Malvern, PA USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Oesingmann, Niels
[3
]
Song, Ting
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Columbia Univ, Dept Biomed Engn, New York, NY USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Song, Ting
[1
,4
]
Lee, Vivian S.
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, New York, NY 10016 USANYU, Sch Med, Dept Radiol, New York, NY 10016 USA
Lee, Vivian S.
[1
]
机构:
[1] NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
[2] Mayo Clin, Coll Med, Div Nephrol & Hypertens, Rochester, MN USA
[3] Siemens Med Solut, Malvern, PA USA
[4] Columbia Univ, Dept Biomed Engn, New York, NY USA
A three-compartment model is proposed for analyzing magnetic resonance renography (MRR) and computed tomography renography (CTR) data to derive clinically useful parameters such as glomerular filtration rate (GFR) and renal plasma flow (RPF). The model fits the convolution of the measured input and the predefined impulse retention functions to the measured tissue curves. A MRR study of 10 patients showed that relative root mean square errors by the model were significantly lower than errors for a previously reported three-compartmental model (11.6%+/- 4.9 vs 15.5%+/- 4.1; P < 0.001). GFR estimates correlated well with reference values by Tc-99m-DTPA scintigraphy (correlation coefficient r = 0.82), and for RPF, r = 0.80. Parameter-sensitivity analysis and Monte Carlo simulation indicated that model parameters could be reliably identified. When the model was applied to CTR in five pigs, expected increases in RPF and GFR due to acetylcholine were detected with greater consistency than with the previous model. These results support the reliability and validity of the new model in computing GFR, RPF, and renal mean transit times from MR and CT data.
机构:
Krankenhaus Wiener Neustadt, Dept Nephrol, Interne Abt 2, A-2700 Wiener Neustadt, AustriaKrankenhaus Wiener Neustadt, Dept Nephrol, Interne Abt 2, A-2700 Wiener Neustadt, Austria
机构:
Manchester Royal Infirm, Dept Phys Med, Manchester M13 9WL, Lancs, EnglandManchester Royal Infirm, Dept Phys Med, Manchester M13 9WL, Lancs, England
机构:
Krankenhaus Wiener Neustadt, Dept Nephrol, Interne Abt 2, A-2700 Wiener Neustadt, AustriaKrankenhaus Wiener Neustadt, Dept Nephrol, Interne Abt 2, A-2700 Wiener Neustadt, Austria
机构:
Manchester Royal Infirm, Dept Phys Med, Manchester M13 9WL, Lancs, EnglandManchester Royal Infirm, Dept Phys Med, Manchester M13 9WL, Lancs, England