Detection of daily physical activities using a triaxial accelerometer

被引:158
作者
Mathie, MJ
Coster, ACF
Lovell, NH [1 ]
Celler, BG
机构
[1] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
[2] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW, Australia
关键词
triaxial accelerometer; energy; activity detection; movement;
D O I
10.1007/BF02348434
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Triaxial accelerometers have been employed to monitor human movements in a variety of circumstances. The study considered the use of data from a single waist-mounted triaxial accelerometer to distinguish between activity states and rest. A method using acceleration magnitude was applied to data collected from 26 normal subjects performing sit-to-stand and stand-to-sit transitions and walking. The effects of three parameters were investigated. the length n of a smoothing median filter, the width w of the averaging window used to process the signal and the value of the acceleration magnitude threshold th. These were found to be inter-related, and sets of parameters that resulted in accurate discrimination were determined by the relationship between th and the product of w and n, and by the relationship between n and w. The subjects were randomly divided into control (N = 13) and test (N = 13) groups. Optimum parameter sets were determined using the control group. Eleven sets of parameters yielded the same optimum results of a sensitivity of 1.0 and a specificity of 0.96 in the control group. Upon application to the test group, using these parameters, the system successfully distinguished between activity and rest, giving sensitivities greater than 0.98 and specificities between 0.88 and 0.94.
引用
收藏
页码:296 / 301
页数:6
相关论文
共 15 条
[1]   A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity [J].
Bouten, CVC ;
Koekkoek, KTM ;
Verduin, M ;
Kodde, R ;
Janssen, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :136-147
[2]   Improving energy expenditure estimation by using a triaxial accelerometer [J].
Chen, KY ;
Sun, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) :2112-2122
[3]   RECORDING ACCELERATIONS IN BODY MOVEMENTS [J].
EVANS, AL ;
DUNCAN, G ;
GILCHRIST, W .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) :102-104
[4]   Assessment of posture and motion by multichannel piezoresistive accelerometer recordings [J].
Fahrenberg, J ;
Foerster, F ;
Smeja, M ;
Muller, W .
PSYCHOPHYSIOLOGY, 1997, 34 (05) :607-612
[5]   Motion pattern and posture: Correctly assessed by calibrated accelerometers [J].
Foerster, F ;
Fahrenberg, J .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2000, 32 (03) :450-457
[6]   Validity and reliability of triaxial accelerometers for inclinometry in posture analysis [J].
Hansson, GÅ ;
Asterland, P ;
Holmer, NG ;
Skerfving, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (04) :405-413
[7]   Analysis of the sit-stand-sit movement cycle in normal subjects [J].
Kerr, KM ;
White, JA ;
Barr, DA ;
Mollan, RAB .
CLINICAL BIOMECHANICS, 1997, 12 (04) :236-245
[8]  
MATHIE M, 2001, 23 ANN INT C IEEE EN
[9]  
Munro BJ, 1998, J BIOMECH, V31, P263, DOI 10.1016/S0021-9290(97)00130-9
[10]  
Murakami D, 1997, METHOD INFORM MED, V36, P360