Effect of liquid and paste-type lubricants on torque values during simulated rotary root canal instrumentation

被引:38
作者
Peters, OA
Boessler, C
Zehnder, M
机构
[1] Univ Zurich, Ctr Dent Med, Dept Prevent Dent Periodontol & Cariol, Div Endodontol, CH-8028 Zurich, Switzerland
[2] Univ Calif San Francisco, Sch Dent, Dept Prevent & Restorat Dent Sci, Endodont Div, San Francisco, CA 94143 USA
关键词
EDTA; instrument fracture; lubricant; torque value;
D O I
10.1111/j.1365-2591.2005.00937.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the effects of lubrication on torque generated during rotary preparation of simulated root canals in dentine using ProFile and ProTaper Nickel-Titanium instruments. Methodology Thirty-two 3 mm thick dentine discs were used for this study. Four pilot holes were drilled perpendicularly through each disc. These simulated root canals were filled with water, aqueous 15% ethylenediamine tetraacetic acid (EDTA) or a paste-type lubricant (Glyde). Empty canals served as controls. Peak torque values and apically directed forces of rotary instruments were measured using a specially designed testing platform. Full torsional loads over time were calculated by integration of continuous torque records. Data were compared using analyses of variance with the alpha-type error set at 0.05. Results Maximum torque values using ProFile instruments were significantly (P < 0.005) reduced by the EDTA solution, whilst no reduction was observed using Glyde. With ProTaper instruments, no lubricant effects on maximum torque values were observed (P = 0.372). Full torsional loads over time were significantly reduced for both ProFile and ProTaper preparation (P < 0.005) by the use of lubrication. The two fluids performed significantly better than paste-based Glyde. All lubricants reduced force when applied to ProTaper by mean reductions ranging from 12 to 54%, whilst Glyde lead to increased force when applied to ProFile. Conclusions Under the conditions of this laboratory study, lubrication appeared to be advantageous. Aqueous solutions generally performed better than the paste-type product under investigation, which showed untoward effects when used in conjunction with a rotary instrument with a U-shaped cross-section (ProFile).
引用
收藏
页码:223 / 229
页数:7
相关论文
共 18 条
[1]   Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments [J].
Blum, JY ;
Cohen, A ;
Machtou, P ;
Micallef, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (01) :24-31
[2]   Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy [J].
Eggert, C ;
Peters, O ;
Barbakow, F .
JOURNAL OF ENDODONTICS, 1999, 25 (07) :494-497
[3]   Interactions of ethylenediamine tetraacetic acid with sodium hypochlorite in aqueous solutions [J].
Grawehr, M ;
Sener, B ;
Waltimo, T ;
Zehnder, M .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (06) :411-415
[4]   Chelating agents in root canal treatment:: mode of action and indications for their use [J].
Hülsmann, M ;
Heckendorff, M ;
Lennon, A .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (12) :810-830
[5]   The mechanical properties of human dentin: A critical review and re-evaluation of the dental literature [J].
Kinney, JH ;
Marshall, SJ ;
Marshall, GW .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2003, 14 (01) :13-29
[6]  
Newitter D A, 1989, Am J Dent, V2, P81
[7]  
Ostby NB., 1957, ODONTOL TIDSKR, V65, P3
[8]   ProTaper rotary root canal preparation:: assessment of torque and force in relation to canal anatomy [J].
Peters, OA ;
Peters, CI ;
Schönenberger, K ;
Barbakow, F .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (02) :93-99
[9]   Dynamic torque and apical forces of ProFile .04 rotary instruments during preparation of curved canals [J].
Peters, OA ;
Barbakow, F .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (04) :379-389
[10]  
Ruddle C., 2002, PATHWAYS PULP, P231