Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular Perimount Magna bioprosthesis in the aortic position

被引:47
作者
Botzenhardt, F [1 ]
Eichinger, WB [1 ]
Guenzinger, R [1 ]
Bleiziffer, S [1 ]
Wagner, I [1 ]
Bauernschmitt, R [1 ]
Lange, R [1 ]
机构
[1] German Heart Ctr, Dept Cardiovasc Surg, D-8000 Munich, Germany
关键词
aortic valve replacement; bioprosthesis; hemodynamics; patient-prosthesis mismatch;
D O I
10.1055/s-2005-837678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Complete supraannular placement and smaller stent design allow the implantation of a Perimount Magna bioprosthesis with a larger inner diameter than that of a standard Perimount. This study compares the hemodynamic performance and the incidence of patient-prosthesis mismatch (PPM) of both prostheses. Methods: 128 patients underwent aortic valve replacement, receiving either a Magna (n = 57) or a standard (n = 71) prosthesis. Inner aortic annulus diameter was measured intraoperatively by a hegar dilator to match echocardiographically obtained results to the annulus diameter instead of matching them to labelled valve size. Results: The Magna was significantly superior with respect to mean pressure gradient and effective orifice area in patients with an annulus diameter of 22 - 23 mm. In patients with an annulus diameter < 22 mm or > 23 mm, there was a non-significant trend towards superior hemodynamics in the Magna group. Severe PPM (effective orifice area index <= 0.65 cm(2)/m(2)) Was present in 11.1% (Magna) vs. 42.1% (Standard) of patients with an annulus diameter < 22 mm; in 0% (Magna) vs. 13.8% (Standard) with an annulus diameter of 22-23 mm; no PPM was seen in patients with annulus diameter > 23 mm in both groups. Conclusions: The Perimount Magna had a significantly reduced incidence of patient-prosthesis mismatch and superior hemodynamics compared to the standard Perimount.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 19 条
[1]   Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis [J].
Banbury, MK ;
Cosgrove, DM ;
Thomas, JD ;
Blackstone, EH ;
Rajeswaran, J ;
Okies, JE ;
Frater, RM .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1460-1465
[2]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[3]   Mid-term hemodynamic and clinical results of the stented porcine Medtronic Mosaic valve in aortic position [J].
Botzenhardt, F ;
Gansera, B ;
Kemkes, BM .
THORACIC AND CARDIOVASCULAR SURGEON, 2004, 52 (01) :34-41
[4]   THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - 10-YEAR RESULTS [J].
COSGROVE, DM ;
LYTLE, BW ;
TAYLOR, PC ;
CAMACHO, MT ;
STEWART, RW ;
MCCARTHY, PM ;
MILLER, DP ;
PIEDMONTE, MR ;
LOOP, FD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03) :651-662
[5]   Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis [J].
Dellgren, G ;
David, TE ;
Raanani, E ;
Armstrong, S ;
Ivanov, J ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) :146-154
[6]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[7]  
DUMESNIL JG, 1992, EUR J CARDIO-THORAC, V6, P34
[8]  
Eichinger WB, 2004, J HEART VALVE DIS, V13, P382
[9]   European experience with the Mosaic bioprosthesis [J].
Eichinger, WB ;
Botzenhardt, F ;
Gunzinger, R ;
Kemkes, BM ;
Sosnowski, A ;
Maïza, D ;
Coto, EO ;
Bleese, N .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) :333-339
[10]   Effects of valve substitute on changes in left ventricular function and hypertrophy after aortic valve replacement [J].
Jin, XY ;
Zhang, ZM ;
Gibson, DG ;
Yacoub, MH ;
Pepper, JR .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :683-690