Inferior vena cava filter migration to right ventricle with destruction of tricuspid valve: A case report

被引:14
作者
Adair, James Devin [1 ]
Harvey, Kyle P. [1 ]
Mahmood, Ali [1 ]
机构
[1] St Joseph Mercy Oakland Hosp, Pontiac, MI 48341 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 02期
关键词
KIMRAY-GREENFIELD FILTER;
D O I
10.1097/TA.0b013e318058251c
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Inferior vena cava filter migration is an uncommon event. Temporary inferior vena cava filters offer protection against pulmonary embolism in the trauma patient in whom anticoagulation is contraindicated. We present the case of a 53-year-old man who suffered a lower extremity injury, which left him unable to walk for an extended period of time. The patient developed a deep venous thrombosis in the early postoperative course and decision was made to place a retrievable inferior vena cava (IVC) filter. One week later the IVC.filter had migrated to the right ventricle and destroyed the tricuspid valve. Al- though there are a limited number of cases describing the migration of IVC filters to the heart, there have been no cases in the literature, to our knowledge, where an IVC filter has destroyed the tricuspid valve and required valve replacement.
引用
收藏
页码:509 / 511
页数:3
相关论文
共 12 条
[1]  
ATKINS CW, 1980, ARCH SURG-CHICAGO, V115, P1133
[2]   CARDIAC-ARRHYTHMIAS FROM A MALPOSITIONED GREENFIELD FILTER IN A TRAUMATIC QUADRIPLEGIC [J].
BACH, JR ;
ZANEUSKI, R ;
LEE, H .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1990, 69 (05) :251-253
[3]   MIGRATION OF A KIMRAY-GREENFIELD FILTER TO THE RIGHT VENTRICLE [J].
CASTANEDA, F ;
HERRERA, M ;
CRAGG, AH ;
SALAMONOWITZ, E ;
LUND, G ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1983, 149 (03) :690-690
[4]   MIGRATED KIMRAY-GREENFIELD FILTER LODGED IN THE RIGHT VENTRICLE - SURGICAL REMOVAL AND TRANSATRIAL REINSERTION [J].
DORSEY, R ;
BAYAZID, S ;
DIETHRICH, EB .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (06) :1230-1231
[5]   PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS - FOLLOW-UP OF 7 DESIGNS IN 320 PATIENTS [J].
FERRIS, EJ ;
MCCOWAN, TC ;
CARVER, DK ;
MCFARLAND, DR .
RADIOLOGY, 1993, 188 (03) :851-856
[6]   MIGRATION OF A GREENFIELD FILTER TO THE PULMONARY-ARTERY - A CASE-REPORT [J].
FRIEDELL, ML ;
GOLDENKRANZ, RJ ;
PARSONNET, V ;
ALPERT, J ;
BRIEF, DK ;
BRENER, BJ ;
AUERON, FM .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (06) :929-931
[7]   Quality improvement guidelines for percutaneous permanent inferior vena cava filter placement for the prevention of pulmonary embolism [J].
Grassi, CJ ;
Swan, TL ;
Cardella, JF ;
Meranze, SG ;
Oglevie, SB ;
Omary, RA ;
Roberts, AC ;
Sacks, D ;
Silverstein, MI ;
Towbin, RB ;
Lewis, CA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (02) :137-141
[8]  
Izutani H, 2004, CAN J CARDIOL, V20, P233
[9]   Tricuspid insufficiency after intracardiac migration of a Greenfield filter: Case report and review of the literature [J].
James, KV ;
Sobolewski, AP ;
Lohr, JM ;
Welling, RE .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (03) :494-498
[10]   A COMPLICATION FOLLOWING KIMRAY-GREENFIELD FILTER INSERTION [J].
LEITER, B ;
SEQUEIRA, J ;
WEITZMAN, AF ;
MENZOIAN, J .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1981, 4 (03) :215-217