Effect of sustained elevated temperature prior to amplification on template copy number estimation using digital polymerase chain reaction

被引:26
作者
Bhat, Somanath [1 ]
McLaughlin, Jacob L. H. [1 ]
Emslie, Kerry R. [1 ]
机构
[1] Natl Measurement Inst, Lindfield, NSW, Australia
关键词
DNA-DAMAGE; PCR; QUANTIFICATION; DENATURATION; DEGRADATION; FIDELITY;
D O I
10.1039/c0an00484g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Digital polymerase chain reaction (dPCR) has the potential to enable accurate quantification of target DNA copy number provided that all target DNA molecules are successfully amplified. Following duplex dPCR analysis from a linear DNA target sequence that contains single copies of two independent template sequences, we have observed that amplification of both templates in a single partition does not always occur. To investigate this finding, we heated the target DNA solution to 95 degrees C for increasing time intervals and then immediately chilled on ice prior to preparing the dPCR mix. We observed an exponential decline in estimated copy number (R-2 >= 0.98) of the two template sequences when amplified from either a linearized plasmid or a 388 base pair (bp) amplicon containing the same two template sequences. The distribution of amplifiable templates and the final concentration (copies per mu L) were both affected by heat treatment of the samples at 95 degrees C from 0 s to 30 min. The proportion of target sequences from which only one of the two templates was amplified in a single partition (either 1507 or hmg only) increased over time, while the proportion of target sequences where both templates were amplified (1507 and hmg) in each individual partition declined rapidly from 94% to 52% (plasmid) and 88% to 31% (388 bp amplicon) suggesting an increase in number of targets from which both templates no longer amplify. A 10 min incubation at 95 degrees C reduced the initial amplifiable template concentration of the plasmid and the 388 bp amplicon by 59% and 91%, respectively. To determine if a similar decrease in amplifiable target occurs during the default pre-activation step of typical PCR amplification protocol, we used mastermixes with a 20 s or 10 min hot-start. The choice of mastermix and consequent pre-activation time did not affect the estimated plasmid concentration. Therefore, we conclude that prolonged exposure of this DNA template to elevated temperatures could lead to significant bias in dPCR measurements. However, care must be taken when designing PCR and non-PCR based experiments by reducing exposure of the DNA template to sustained elevated temperatures in order to improve accuracy in copy number estimation and concentration determination.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 24 条
[1]   Self-catalyzed site-specific depurination of guanine residues within gene sequences [J].
Amosova, O ;
Coulter, R ;
Fresco, JR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (12) :4392-4397
[2]  
Antonescu CR, 2008, CANCER INFORM, V6, P59
[3]   Comparison of Methods for Accurate Quantification of DNA Mass Concentration with Traceability to the International System of Units [J].
Bhat, Somanath ;
Curach, Natalie ;
Mostyn, Thomas ;
Bains, Gursharan Singh ;
Griffiths, Kate R. ;
Emslie, Kerry R. .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7185-7192
[4]   Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number [J].
Bhat, Somanath ;
Herrmann, Jan ;
Armishaw, Paul ;
Corbisier, Philippe ;
Emslie, Kerry R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) :457-467
[5]   Absolute quantification of genetically modified MON810 maize (Zea mays L.) by digital polymerase chain reaction [J].
Corbisier, Philippe ;
Bhat, Somanath ;
Partis, Lina ;
Xie, Vicki Rui Dan ;
Emslie, Kerry R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (06) :2143-2150
[6]   Base-excision repair of oxidative DNA damage [J].
David, Sheila S. ;
O'Shea, Valerie L. ;
Kundu, Sucharita .
NATURE, 2007, 447 (7147) :941-950
[7]  
DOUGLAS A, 1993, PCR METH APPL, V3, P133
[8]   Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device [J].
Dube, Simant ;
Qin, Jian ;
Ramakrishnan, Ramesh .
PLOS ONE, 2008, 3 (08)
[9]  
DURATE V, 1999, NUCLEIC ACIDS RES, V27, P496
[10]   Identifying distinct classes of bladder carcinoma using microarrays [J].
Dyrskjot, L ;
Thykjaer, T ;
Kruhoffer, M ;
Jensen, JL ;
Marcussen, N ;
Hamilton-Dutoit, S ;
Wolf, H ;
Orntoft, TF .
NATURE GENETICS, 2003, 33 (01) :90-96