In vivo tear-film thickness determination and implications for tear-film stability

被引:100
作者
Creech, JL
Do, LT
Fatt, I
Radke, CJ
机构
[1] Univ Calif Berkeley, Dept Chem Engn, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
关键词
breakup; evaporation; stability; tear film; thickness;
D O I
10.1076/ceyr.17.11.1058.5233
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Previous measurements of tear-film thickness in vivo are limited and cannot be easily applied in a clinical setting. A novel technique to measure tear-film thickness indirectly is introduced here, requiring only a slit lamp, video camera, and computer. A recent fluid mechanical theory relates tear-film thickness h, to the tear meniscus radius R, tear surface tension sigma, tear viscosity mu, and upper lid velocity U. This theory yields the result that h/R = 2.12 (mu U/sigma)(2/3). All parameters except h/R are taken as known physical constants, and R was measured for each subject, allowing the above equation to establish h. Tear-film breakup was also evaluated and correlated with tear-film thickness. Methods. A clinical study was performed in which aqueous tear-film thickness was determined for 45 subjects, including 24 non-lens subjects, 15 hydrogel contact lens wearers, and 6 RGP lens wearers. R was measured by instilling fluorescein dye in the form of an eyedrop and videotaping the tear meniscus in profile. Tear-film breakup was videotaped through the ocular port of the slit lamp and evaluated based on a severity scale. Results. Aqueous tear-film measurements are in the same range as literature values, with most measured values falling between 6 and 12 mu m. Average tear-film thicknesses for non-lens, hydrogel, and RGP subjects are 10.4, 6.5, and 5.8 mu m, respectively. Tear-film breakup is most severe in subjects with thin tear films, especially in contact-lens wearers. Conclusions. Tear-him thickness is an important parameter that varies among individuals. These variations correlate with differences in tear-film stability.
引用
收藏
页码:1058 / 1066
页数:9
相关论文
共 34 条
[21]   AGE-RELATED-CHANGES IN PRECORNEAL TEAR FILM STABILITY [J].
PATEL, S ;
FARRELL, JC .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (03) :175-178
[22]   COMPARISON OF TEAR FILM THICKNESS IN 3 SPECIES DETERMINED BY THE GLASS-FIBER METHOD AND CONFOCAL MICROSCOPY [J].
PRYDAL, JI ;
MUIR, MGK ;
DILLY, PN .
EYE, 1993, 7 :472-475
[23]  
PRYDAL JI, 1992, INVEST OPHTH VIS SCI, V33, P1996
[24]  
PRYDAL JI, 1992, INVEST OPHTH VIS SCI, V33, P2006
[25]  
PRYDAL JI, 1995, SCANNING, V17, P133, DOI 10.1002/sca.4950170301
[26]  
REFOJO MF, 1986, PREOCULAR TEAR FILM, P117
[27]   TEAR EVAPORIMETER FOR MEASURING WATER EVAPORATION RATE FROM THE TEAR FILM UNDER CONTROLLED CONDITIONS IN HUMANS [J].
ROLANDO, M ;
REFOJO, MF .
EXPERIMENTAL EYE RESEARCH, 1983, 36 (01) :25-33
[28]   PHYSIOLOGICAL FUNCTIONS OF THE MEIBOMIAN GLANDS [J].
TIFFANY, JM .
PROGRESS IN RETINAL AND EYE RESEARCH, 1995, 14 (01) :47-74
[29]   TEAR FILM STABILITY AND TEAR SURFACE-TENSION [J].
TIFFANY, JM ;
WINTER, N ;
BLISS, G .
CURRENT EYE RESEARCH, 1989, 8 (05) :507-515
[30]   THE VISCOSITY OF HUMAN TEARS [J].
TIFFANY, JM .
INTERNATIONAL OPHTHALMOLOGY, 1991, 15 (06) :371-376