Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter - Comparison of contact and reconstructed electrograms during sinus rhythm

被引:237
作者
Schilling, RJ
Peters, NS
Davies, W
机构
[1] St Marys Hosp, Waller Dept Cardiol, London W2 1NY, England
[2] Univ London Imperial Coll Sci Technol & Med, Sch Med, London, England
关键词
mapping; tachyarrhythmia; electrophysiology;
D O I
10.1161/01.CIR.98.9.887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and morphology of reconstructed unipolar electrograms compared with contact unipolar electrograms from the same endocardial site. Methods and Results-The MEA was deployed in the left ventricles of 13 patients (end-diastolic diameters, 61.7+/-8.4 mm [mean+SD]), We recorded contact electrograms at 76 points equatorial and 32 points nonequatorial to the MEA during sinus rhythm using a catheter-locator signal to record direction and distance from the MEA. Morphology (crosscorrelation) and timing of maximum -dV/dt of contact and reconstructed electrograms were compared at different distances from the MEA center to endocardium (M-E) and from the MEA equatorial plane. For equatorial data, the M-E was 32.12+/-12.12 mm. The timing of reconstructed with respect to contact electrograms was -1.94+/-7.12 ms for M-E <34 mm and -14.16+/-19.29 ms at M-E >34 mm (P<0.001). Cross-correlation of electrograms was 0.87+/-0.12 (95% CI, 0.84 to 0.91) and 0.76+/-0.18 (95% CI, 0.69 to 0.83) for M-E <34 mm and >34 mm, respectively. Nonequatorial points were 32.33+/-10.81 mm (range, 16.9 to 55.6 mm) from the MEA equatorial plane; electrogram timing difference was -8.97+/-15.75 ms and was unrelated to this distance from the equator. Conclusions-This noncontact mapping system accurately reconstructs endocardial unipolar electrograms from the human left ventricle. At M-E distances >34 mm, timing accuracy of reconstruction decreases.
引用
收藏
页码:887 / 898
页数:12
相关论文
共 34 条
  • [1] BEATTY GE, 1994, PACING CLIN ELECTROP, V17, P765
  • [2] MANAGEMENT OF PATIENTS WITH VENTRICULAR TACHYARRHYTHMIAS - DOES AN OPTIMAL THERAPY EXIST
    BOCKER, D
    BREITHARDT, G
    BLOCK, M
    BORGGREFE, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (03): : 559 - 570
  • [3] BORGGREFE M, 1994, CATHETER ABLATION AR, P277
  • [4] DIGITAL SIGNAL-PROCESSING CHIP IMPLEMENTATION FOR DETECTION AND ANALYSIS OF INTRACARDIAC ELECTROGRAMS
    CHIANG, CMJ
    JENKINS, JM
    DICARLO, LA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (08): : 1373 - 1379
  • [5] VENTRICULAR-TACHYCARDIA IN THE INFARCTED, LANGENDORFF-PERFUSED HUMAN HEART - ROLE OF THE ARRANGEMENT OF SURVIVING CARDIAC FIBERS
    DEBAKKER, JMT
    CORONEL, R
    TASSERON, S
    WILDE, AAM
    OPTHOF, T
    JANSE, MJ
    VANCAPELLE, FJL
    BECKER, AE
    JAMBROES, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (07) : 1594 - 1607
  • [6] ENDOCARDIAL MAPPING OF VENTRICULAR-TACHYCARDIA IN THE INTACT HUMAN VENTRICLE .3. EVIDENCE OF MULTIUSE REENTRY WITH SPONTANEOUS AND INDUCED BLOCK IN PORTIONS OF REENTRANT PATH COMPLEX
    DOWNAR, E
    SAITO, J
    DOIG, JC
    CHEN, TCK
    SEVAPTSIDIS, E
    MASSE, S
    KIMBER, S
    MICKLEBOROUGH, L
    HARRIS, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) : 1591 - 1600
  • [7] REENTRANT VENTRICULAR ARRHYTHMIAS IN THE LATE MYOCARDIAL-INFARCTION PERIOD - INTERRUPTION OF REENTRANT CIRCUITS BY CRYOTHERMAL TECHNIQUES
    ELSHERIF, N
    MEHRA, R
    GOUGH, WB
    ZEILER, RH
    [J]. CIRCULATION, 1983, 68 (03) : 644 - 656
  • [8] Gepstein L, 1997, CIRCULATION, V95, P1611
  • [9] GORNICK CC, IN PRESS CIRCULATION
  • [10] IDENTIFICATION OF VENTRICULAR-TACHYCARDIA USING INTRACARDIAC ELECTROGRAMS - A COMPARISON OF UNIPOLAR VERSUS BIPOLAR WAVE-FORM ANALYSIS
    GREENHUT, SE
    DICARLO, LA
    JENKINS, JM
    THRONE, RD
    WINSTON, SA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (03): : 427 - 433