A comparison between ELISPOT methods for the detection of cytokine producing cells: Greater sensitivity and specificity using ELISA plates as compared to nitrocellulose membranes

被引:39
作者
Ronnelid, J
Klareskog, L
机构
[1] Department of Rheumatology, Karolinska Hospital, Stockholm
[2] Department of Medicine, Rheumatology Unit, Rheumatology Research Laboratory
关键词
ELISPOT; IL-4; IFN-gamma; kinetic study;
D O I
10.1016/S0022-1759(96)00170-6
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
We have used the ELISPOT method employing plastic ELISA plates without substrate in agar for the detection of single cells producing interferon-gamma (IFN-gamma) and interleukin-4 (IL-4). When using PBMC directly stimulated in the assay wells with T cell mitogens it was possible to measure production of human IFN-gamma at an earlier time point and with a higher sensitivity compared to conventional nitrocellulose plates. The plastic surface was not autostimulatory for IFN-gamma production, as seems to be the case for nitrocellulose surfaces. Compared to the use of nitrocellulose plates, the use of plastic ELISA plates is considerably cheaper and easier to perform. The increased sensitivity for cytokine detection, together with minimal autostimulatory properties of the detection surface, makes this method suitable for the detection of spontaneous low grade cytokine production from cells obtained in vivo.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 8 条
[1]
REVERSE ELISPOT ASSAY FOR CLONAL ANALYSIS OF CYTOKINE PRODUCTION .1. ENUMERATION OF GAMMA-INTERFERON-SECRETING CELLS [J].
CZERKINSKY, C ;
ANDERSSON, G ;
EKRE, HP ;
NILSSON, LA ;
KLARESKOG, L ;
OUCHTERLONY, O .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 110 (01) :29-36
[2]
A SOLID-PHASE ENZYME-LINKED IMMUNOSPOT (ELISPOT) ASSAY FOR ENUMERATION OF SPECIFIC ANTIBODY-SECRETING CELLS [J].
CZERKINSKY, CC ;
NILSSON, LA ;
NYGREN, H ;
OUCHTERLONY, O ;
TARKOWSKI, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 65 (1-2) :109-121
[3]
HOWELL WM, 1991, CLIN EXP IMMUNOL, V86, P393
[4]
INCREASED NUMBERS OF T-CELLS RECOGNIZING MULTIPLE MYELIN BASIC-PROTEIN EPITOPES IN MULTIPLE-SCLEROSIS [J].
OLSSON, T ;
SUN, JB ;
HILLERT, J ;
HOJEBERG, B ;
EKRE, HP ;
ANDERSSON, G ;
OLERUP, O ;
LINK, H .
EUROPEAN JOURNAL OF IMMUNOLOGY, 1992, 22 (04) :1083-1087
[5]
A SOLID-PHASE IMMUNOENZYMATIC TECHNIQUE FOR THE ENUMERATION OF SPECIFIC ANTIBODY-SECRETING CELLS [J].
SEDGWICK, JD ;
HOLT, PG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 57 (1-3) :301-309
[6]
ENUMERATION OF IFN-GAMMA-PRODUCING HUMAN-LYMPHOCYTES BY SPOT-ELISA - A METHOD TO DETECT LYMPHOKINE-PRODUCING LYMPHOCYTES AT THE SINGLE-CELL LEVEL [J].
VERSTEEGEN, JMT ;
LOGTENBERG, T ;
BALLIEUX, RE .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 111 (01) :25-29
[7]
WANG WZ, 1992, CLIN EXP IMMUNOL, V88, P157
[8]