An amperometric glucose biosensor with enhanced measurement stability and sensitivity using an artificially porous conductin polymer

被引:22
作者
Ekanayake, E. M. I. Mala [1 ]
Preethichandra, D. M. G. [1 ]
Kaneto, Keiichi [1 ]
机构
[1] Kyushu Inst Technol, Grad Sch Life Sci & Syst Engn, Kitakyushu, Fukuoka 8080196, Japan
基金
日本学术振兴会;
关键词
alumina; artificial porosity; cross-linking; nanoporous; polypyrrole (PPy);
D O I
10.1109/TIM.2008.922068
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A conducting polymer [polypyrrole (PPy)]-based amperometric biosensor fabricated on a platinum-coated nanoporous alumina electrode has been described. This fabricating process introduced artificial porosity into the PPy film, and the template pore sizes were carefully chosen to match the size of the glucose oxidase (GOx) molecule. The PF 6 -doped PPy film was synthesized with 0.05 M pyrrole and 0.1 M NaPF6 at a current density of 0.3 mA/CM2 for 90 s. Immobilization was done by physically adsorbing 5 pL of GOx on the nanoporous PPy film. Glutaraldehyde (0.1 wt.%, 5 pL) was used for cross-finking. The synthesized films were characterized by using an electrochemical technique and scanning electron microscopy (SEM). Amperometric responses were measured as a function of different concentrations of glucose at 0.4 V. Nanoporous electrodes lead to high enzyme loading, whereas the use of a cross-linking agent increased stability, sensitivity, reproducibility, repeatability, and shelf life.
引用
收藏
页码:1621 / 1626
页数:6
相关论文
共 19 条
[11]   A Clark-type oxidase enzyme-based amperometric microbiosensor for sensing glucose, galactose, or choline [J].
Peteu, SF ;
Emerson, D ;
Worden, RM .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) :1059-1071
[12]   Amperometric tyrosinase based biosensor using an electropolymerized PTS-doped polypyrrole film as an entrapment support [J].
Rajesh ;
Takashima, W ;
Kaneto, K .
REACTIVE & FUNCTIONAL POLYMERS, 2004, 59 (02) :163-169
[13]   Electrochemical sensors based on conducting polymer- polypyrrole [J].
Ramanavicius, A. ;
Ramanaviciene, A. ;
Malinauskas, A. .
ELECTROCHIMICA ACTA, 2006, 51 (27) :6025-6037
[14]   A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment [J].
Shan, Dan ;
He, Yuanyuan ;
Wang, Shanxia ;
Xue, Huaiguo ;
Zheng, Hao .
ANALYTICAL BIOCHEMISTRY, 2006, 356 (02) :215-221
[15]  
SWOBODA BEP, 1965, J BIOL CHEM, V240, P2209
[16]   BIOSENSORS BASED ON OXIDASES IMMOBILIZED IN VARIOUS CONDUCTING POLYMERS [J].
TROJANOWICZ, M ;
GESCHKE, O ;
KRAWCZYK, TKV ;
CAMMANN, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) :191-199
[17]  
Verghese MM, 1998, J APPL POLYM SCI, V70, P1447, DOI 10.1002/(SICI)1097-4628(19981121)70:8<1447::AID-APP3>3.0.CO
[18]  
2-4
[19]  
WILSON K, 2000, PRACTICAL BIOCH