Binding and lysing of blood clots using MRX-408

被引:97
作者
Wu, YQ
Unger, EC
McCreery, TP
Sweitzer, RH
Shen, DK
Wu, GL
Vielhauer, MD
机构
[1] ImaRx Pharmaceut Corp, Tucson, AZ 85719 USA
[2] Univ Arizona, Ctr Hlth Sci, Dept Radiol, Tucson, AZ USA
关键词
thrombolysis; microbubbles; ultrasound; contrast agent; drug delivery;
D O I
10.1097/00004424-199812000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. A thrombus-specific ultrasound contrast agent, MRX-408, has been developed recently. This agent consists of phospholipid-coated microbubbles with a ligand capable of targeting the GPllb/IIIa receptor, thereby allowing the microbubbles to bind with thrombi rich in activated platelets, In vitro and in vivo animal experiments have been conducted to examine imaging enhancement and sonothrombulysis using this agent compared with a nontargeted agent, METHODS. For clot binding, blood-smeared slides were incubated with microbubbles and examined under a light microscope, Change in backscatter signals from the:blood clots after binding was examined by both an ultrasound scanner and two single-element transducers arranged in a transmitter-receiver pair. For clot lysis, either 1-MHz or 20-KHz ultrasound was used to enhance the lysing effects of MRX-408 with or without urokinase, RESULTS. Evidence of binding was demonstrated under a microscope. In vitro experiments showed that the "acoustic signature," or properties, of blood clots changed after binding. Clots became more echogenic and nonlinear. In vivo fundamental ultrasound imaging confirmed that as a result of binding, blood clots were more visible, the area of detection was improved, and shadowing behind clots was more noticeable, Under 1-MHz ultrasound and 30 minutes of treatment, lysis efficiency reached 34% with MRX-408, whereas there was no visible clot lysis with saline. CONCLUSION. The results of these preliminary studies show that as a contrast agent, MRX-408 enhanced clots under ultrasound imaging and facilitated sonothrombolysis with or without thrombolytic drugs.
引用
收藏
页码:880 / 885
页数:6
相关论文
共 15 条
[1]  
CHANDLER AB, 1958, LAB INVEST, V7, P110
[2]   ENHANCEMENT OF FIBRINOLYSIS INVITRO BY ULTRASOUND [J].
FRANCIS, CW ;
ONUNDARSON, PT ;
CARSTENSEN, EL ;
BLINC, A ;
MELTZER, RS ;
SCHWARZ, K ;
MARDER, VJ .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 90 (05) :2063-2068
[3]   Transcutaneous ultrasound augments lysis of arterial thrombi in vivo [J].
Luo, H ;
Nishioka, T ;
Fishbein, MC ;
Cercek, B ;
Forrester, JS ;
Kim, CJ ;
Berglund, H ;
Siegel, RJ .
CIRCULATION, 1996, 94 (04) :775-778
[4]   ENHANCEMENT OF THROMBOLYSIS BY EXTERNAL ULTRASOUND [J].
LUO, H ;
STEFFEN, W ;
CERCEK, B ;
ARUNASALAM, S ;
MAURER, G ;
SIEGEL, RJ .
AMERICAN HEART JOURNAL, 1993, 125 (06) :1564-1569
[5]  
METZGER P, 1998, 3 ULTR CONTR RES S R
[6]   PROFIBRINOLYTIC AND ANTIFIBRINOLYTIC EFFECTS OF ULTRASOUND ON STREPTOKINASE-INDUCED THROMBOLYSIS [J].
NILSSON, AM ;
ODSELIUS, R ;
ROIJER, A ;
OLSSON, SB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (06) :833-840
[7]   Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: An in vitro and in vivo study [J].
Nishioka, T ;
Luo, H ;
Fishbein, MC ;
Cercek, B ;
Forrester, JS ;
Kim, CJ ;
Berglund, H ;
Siegel, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (02) :561-568
[8]  
Porter TR, 1996, J ULTRAS MED, V15, P577
[9]   Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles [J].
Porter, TR ;
LeVeen, RF ;
Fox, R ;
Kricsfeld, A ;
Xie, F .
AMERICAN HEART JOURNAL, 1996, 132 (05) :964-968
[10]   ALBUMIN MICROBUBBLE ECHO-CONTRAST MATERIAL AS AN ENHANCER FOR ULTRASOUND ACCELERATED THROMBOLYSIS [J].
TACHIBANA, K ;
TACHIBANA, S .
CIRCULATION, 1995, 92 (05) :1148-1150