Exploring the limits of bacterial identification by intact cell-mass spectrometry

被引:40
作者
Evason, DJ
Claydon, MA
Gordon, DB
机构
[1] Qual Management Ltd, Bury BL9 9BW, Lancs, England
[2] Manchester Metropolitan Univ, Bioanalyt Res Ctr, Manchester M15 6BH, Lancs, England
关键词
D O I
10.1016/S1044-0305(00)00192-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The limits of intact cell-mass spectrometry (ICM-MS) were tested with regard to the minimum number of bacterial cells detectable and its power to discriminate mixed-bacterial cultures. The technique is a surface analysis tool, as is supported by evidence showing that mass fingerprints correspond to material desorbed directly from the cell wall. The brief exposure to solvents, which occurs during sample preparation, does not extract internal cellular material. Spectra were collected over the m/z range of 500 to 10,000. The UV absorbing matrices used were found to be highly specific to bacterial gram type: alpha -cyano-4-hydroxycinnamic acid for gramnegative bacteria and 5-chloro-2-mercaptobenzothiazole for gram-positive bacteria. This specificity allows mixed cultures of different gram types to be differentiated by ICM-MS. The minimum number of cells that could reliably give spectra of sufficient data was 10(4) cells (10(7) cells/mL). (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 39 条
  • [11] Rapid discrimination between methicillin-sensitive and methicillin-resistant Staphylococcus aureus by intact cell mass spectrometry
    Edwards-Jones, V
    Claydon, MA
    Evason, DJ
    Walker, J
    Fox, AJ
    Gordon, DB
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (03) : 295 - 300
  • [12] Rapid typing and elucidation of new secondary metabolites of intact cyanobacteria using MALDI-TOF mass spectrometry
    Erhard, M
    vonDohren, H
    Jungblut, P
    [J]. NATURE BIOTECHNOLOGY, 1997, 15 (09) : 906 - 909
  • [13] Evason DJ, 2000, RAPID COMMUN MASS SP, V14, P669, DOI 10.1002/(SICI)1097-0231(20000430)14:8<669::AID-RCM932>3.3.CO
  • [14] 2-Z
  • [15] Fenselau C., 1994, ACS S SERIES, V541
  • [16] Use of an internal control for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of bacteria
    Gantt, SL
    Valentine, NB
    Saenz, AJ
    Kingsley, MT
    Wahl, KL
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (11) : 1131 - 1137
  • [17] Pyrolysis mass spectrometry and its applications in biotechnology
    Goodacre, R
    Kell, DB
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 20 - 28
  • [18] GOODFELLOW M, 1995, BINARY-COMPUT MICROB, V7, P54
  • [19] Haag AM, 1998, J MASS SPECTROM, V33, P750, DOI 10.1002/(SICI)1096-9888(199808)33:8<750::AID-JMS680>3.0.CO
  • [20] 2-1