Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis

被引:144
作者
Kaufmann, C
Bachmann, LM
Thiel, MA
机构
[1] Univ Zurich, Dept Ophthalmol, Zurich, Switzerland
[2] Univ Zurich, Horten Ctr Patient Oriented Res, Zurich, Switzerland
关键词
D O I
10.1167/iovs.02-0946
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Thinning of the corneal stroma by laser in situ keratomileusis (LASIK) results in inaccurate low intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Dynamic contour tonometry (DCT) is a novel measuring technique, designed to measure IOP largely independent of corneal thickness and curvature. The purpose of this study was to compare IOP measurements using GAT and DCT in eyes undergoing LASIK for correction of myopia. METHODS. In a prospective, single-center study, central corneal thickness (CCT) and IOP were measured in patients undergoing first-time LASIK for myopia. IOP was measured before and after surgery using GAT and DCT. The untreated contralateral. eyes served as paired controls. RESULTS. There was good concordance between the two tonometers in 62 normal eyes before LASIK. Corneal ablation of 90.0 +/- 49.18 mum (median +/- SD) reduced IOP readings as measured by GAT by 3.0 +/- 1.9 mm Hg (P < 0.001). In contrast, no significant change in IOP readings was recorded by DCT (-0.2 mm Hg +/- 1.5 mm Hg, P = 0.30). There was no change in IOP in the untreated control eyes as measured by GAT and DCT. CONCLUSIONS. Significant decreases in IOP were recorded by GAT after LASIK for myopia. Measurements by DCT, however, did not reveal any significant changes in IOP.
引用
收藏
页码:3790 / 3794
页数:5
相关论文
共 38 条
[1]  
Agudelo LM, 2002, J REFRACT SURG, V18, P472
[2]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[3]   Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) [J].
Brandt, JD ;
Beiser, JA ;
Kass, MA ;
Gordon, MO .
OPHTHALMOLOGY, 2001, 108 (10) :1779-1788
[4]   Falsely elevated intraocular pressure due to increased central corneal thickness [J].
Bron, AM ;
Creuzot-Garcher, C ;
Goudeau-Boutillon, S ;
d'Athis, P .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (03) :220-224
[5]   Non-contact tonometry in patients that underwent photorefractive keratectomy [J].
Cennamo, G ;
Rosa, N ;
LaRana, A ;
Bianco, S ;
Sebastiani, A .
OPHTHALMOLOGICA, 1997, 211 (06) :341-343
[6]   Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia [J].
Chatterjee, A ;
Shah, S ;
Bessant, DA ;
Naroo, SA ;
Doyle, SJ .
OPHTHALMOLOGY, 1997, 104 (03) :355-359
[7]   Principles of contact lens tonometry [J].
Dekker, PW ;
Robert, YCA ;
Kanngiesser, H ;
Pirani, P ;
Entenmann, B .
INTERNATIONAL OPHTHALMOLOGY, 1998, 22 (02) :105-111
[8]   Tonometry after laser in situ keratomileusis treatment [J].
Duch, S ;
Serra, A ;
Castanera, J ;
Abos, R ;
Quintana, M .
JOURNAL OF GLAUCOMA, 2001, 10 (04) :261-265
[9]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[10]   Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis [J].
Emara, B ;
Probst, LE ;
Tingey, DP ;
Kennedy, DW ;
Willms, LJ ;
Machat, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (10) :1320-1325