Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations

被引:9
作者
Armenta, S [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Valencia, Spain
关键词
mancozeb; FTIR determination; pesticide formulations; internal standardization; solid sampling; KBr pellets; PLS;
D O I
10.1016/j.talanta.2004.08.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A series of approaches have been assayed for FTIR determination of Mancozeb in several solid commercial fungicides using different calibration strategies. The simplest procedure was based on the use of the ratio between the absorbance of a characteristic band of Mancozeb and that of a KSCN internal standard measured in the F-FIR spectra obtained from KBr pellets. It was employed the quotient between peak height absorbance values at 1525 cm(-1) for Mancozeb and 2070 cm(-1) for KSCN. In these conditions a precision as relative standard deviation (RSD) of 0.6% and a relative accuracy error of 0.8% (w/w) were found. For complex formulations, containing other compounds with characteristic absorption bands at different wavenumbers than Mancozeb, one of them was used as internal reference being employed the standard addition approach. In this case, the Mancozeb bands at 1525 cm(-1) or at 1289 cm(-1) were employed, being used the ferrocyanide band at 2075 cm(-1) as internal reference. RSD values between 0.7-1.4% and a relative accuracy error of 3% (w/w) were found. A third strategy was based on the use of partial least squares (PLS) calibration. A reference set was prepared mixing Mancozeb, Kaolin, Cymoxanil and KBr, being predicted the Mancozeb concentration in pesticide formulations by using the quotient between absorbance bands of Mancozeb and those of Cymoxanil. In these conditions a relative accuracy error of 0.6% (w/w) and a relative standard deviation of 1.3% were found. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 28 条
[1]   Quantitative analysis of agrochemical formulations by multivariate spectroscopic techniques [J].
Almond, MJ ;
Knowles, SJ .
APPLIED SPECTROSCOPY, 1999, 53 (09) :1128-1137
[2]   Fourier transform infrared spectrometric strategies for the determination of Buprofezin in pesticide formulations [J].
Armenta, S ;
Quintás, G ;
Moros, J ;
Garrigues, S ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 2002, 468 (01) :81-90
[3]   Determination of dithiocarbamate fungicide residues in food by a spectrophotometric method using a vertical disulfide reaction system [J].
Caldas, ED ;
Conceiçao, MH ;
Miranda, MCC ;
de Souza, LCKR ;
Lima, JF .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (10) :4521-4525
[4]   CHARACTERIZATION OF ETHYLENE OXIDE/TERT-OCTYLPHENOL CONDENSATES BY ULTRAVIOLET AND INFRARED SPECTROMETRY [J].
CARRION, JL ;
SAGRADO, S ;
DELAGUARDIA, M .
ANALYTICA CHIMICA ACTA, 1986, 185 :101-107
[5]   Determination of sulfide in waters by flow-injection solid phase spectrophotometry [J].
Cassella, RJ ;
Teixeira, LSG ;
Garrigues, S ;
Costa, ACS ;
Santelli, RE ;
de la Guardia, M .
ANALYST, 2000, 125 (10) :1835-1838
[6]   Fourier transform infrared spectrometric determination of Ziram [J].
Cassella, AR ;
Garrigues, S ;
de Campos, RC ;
de la Guardia, M .
TALANTA, 2001, 54 (06) :1087-1094
[7]  
*CIPAC LTD, 1994, COLL INT PEST AN COU
[8]   A RAPID METHOD FOR THE DETERMINATION OF FAT IN FOODSTUFFS BY INFRARED SPECTROMETRY [J].
CRONIN, DA ;
MCKENZIE, K .
FOOD CHEMISTRY, 1990, 35 (01) :39-49
[9]   Safety evaluation of the fungicide iprodione on cauliflower (Brassica oleracea var. oleracea L.) [J].
Datta, A ;
Gopal, M .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1999, 62 (04) :496-501
[10]   SOME OBSERVATIONS ON THE DETERMINATION OF THE METHYL PARATHION PARATHION RATIO IN BINARY-MIXTURES BY INFRARED-SPECTROSCOPY [J].
DEBENZO, ZA ;
GOMEZ, C ;
MELENDEZ, S ;
DELAGUARDIA, M ;
SALVADOR, A .
MICROCHEMICAL JOURNAL, 1989, 40 (03) :271-276