Fourier transform infrared spectrometric strategies for the determination of Buprofezin in pesticide formulations

被引:32
作者
Armenta, S [1 ]
Quintás, G [1 ]
Moros, J [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
buprofezin; Fourier transform infrared spectrometry; flow injection analysis; stopped-flow; partial least squares; pesticide;
D O I
10.1016/S0003-2670(02)00656-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different strategies for Buprofezin determination, an off-line extraction and stopped-flow determination and an automated procedure, based on the on-line extraction of Buprofezin samples with chloroform and flowing action analysis-fourier transform infrared (FIA-FT-IR) spectrometric measurement of the extracts, have been developed. For the treatment of the off-line extraction mode, data a three-factor partial least squares (PLSs) calibration was developed, using the region from 1465.7 to 1342.3 cm(-1) with a single point baseline defined at 2051.9 cm(-1) and based on the use of chloroform solutions of Buprofezin. The method provides a R.S.D. <0.1%, recoveries of the order of 100% and generates 25 nil of CHCl3 waste for each sample. On the other hand, the recommended FIA method provided a 3 s limit of detection of 20 μg ml(-1), which corresponds to 0.12% (w/w) in the solid sample, a repeatability of 0.8% as R.S.D., and a maximum sampling frequency for the whole procedure of 6 h(-1). The waste generation, being lower than the off-line strategy, is only 3 ml of CHCl3 per sample. © 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 14 条
  • [1] Flow injection Fourier transform infrared determination of caffeine in coffee
    Bouhsain, Z
    Garrigues, JM
    Garrigues, S
    de la Guardia, M
    [J]. VIBRATIONAL SPECTROSCOPY, 1999, 21 (1-2) : 143 - 150
  • [2] Acephate and buprofezin residues in olives and olive oil
    Cabras, P
    Angioni, A
    Garau, VL
    Pirisi, FM
    Cabitza, F
    Pala, M
    [J]. FOOD ADDITIVES AND CONTAMINANTS, 2000, 17 (10): : 855 - 858
  • [3] CADET F, 2000, ENCY ANAL CHEM, P10879
  • [4] Determination of sulfide in waters by flow-injection solid phase spectrophotometry
    Cassella, RJ
    Teixeira, LSG
    Garrigues, S
    Costa, ACS
    Santelli, RE
    de la Guardia, M
    [J]. ANALYST, 2000, 125 (10) : 1835 - 1838
  • [5] DETERMINATION OF PHENYL ISOCYANATE IN A FLOW-INJECTION SYSTEM WITH INFRARED SPECTROMETRIC DETECTION
    CURRAN, DJ
    COLLIER, WG
    [J]. ANALYTICA CHIMICA ACTA, 1985, 177 : 259 - 262
  • [6] DELINAN C, 2000, VADEMECUM PRODUCTOS
  • [7] Flow injection Fourier transform infrared determination of nicotine in tobacco
    Garrigues, JM
    Pérez-Ponce, A
    Garrigues, S
    de la Guardia, M
    [J]. ANALYST, 1999, 124 (05) : 783 - 786
  • [8] GARRIGUES S, 2002, HDB VIBRATIONAL SPEC, V2, P1661
  • [9] Kaihara A, 2000, J HEALTH SCI, V46, P336
  • [10] LINVIEN D, 1991, INFRARED RAMAN CHARA