Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model

被引:74
作者
Abron, A
Hopfensperger, M
Thompson, J
Cooper, LF [2 ]
机构
[1] Univ N Carolina, Dent Res Ctr, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Sch Dent, Dept Prosthodont, Chapel Hill, NC 27599 USA
关键词
D O I
10.1067/mpr.2001.112415
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Alterations in commercially pure titanium (cp Ti) implant surface topography can be made to increase bone formation or the interfacial shear strength of bone at the functioning implant. It is not known whether these 2 goals are congruent or mutually exclusive. Purpose. The aim of this study was to determine the effect of implant surface topography parameters of calculated biomechanical significance on the process of bone formation in a rat tibia model of osseointegration. Material and methods. Implants (cp Ti grade IV) were machined and subsequently treated by grit blasting or grit blasting and 6.4 mol/L HCl. Measurements of surface roughness were made by atomic force microscopic analysis of similarly treated titanium disks. Cleaned and sterilized implants (12 machined, 12 with nonideal pit morphology: 12 with ideal pit morphology) were placed into the tibiae of 400-g male Wistar rats by using a series of drills, irrigation, and a self-tapping procedure, After 3 weeks, tibiae were harvested and processed and embedded in methyl methacrylate resin, Polished sections were examined by backscatter electron microscopy, and the percentage implant surface contacting bone nias measured with the Scionics PC image analysis program. Results. The implants possessing a proposed ideal pit morphology supported significantly greater bone formation at the implant surface (54% +/- 7% bone-to-implant contact [P<.003]) than the nonideal pit morphology (40% +/- 15%) or machined surfaces (34% +/- 6%). Conclusion. Implant surfaces with a proposed ideal pit morphology (which possess a calculated biomechanical significance) enhanced bone formation at early periods after placement in the rat tibia model.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 21 条
[1]  
ALBREKTSSON T, 1990, International Journal of Prosthodontics, V3, P30
[2]   Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat [J].
Branemark, R ;
Ohrnell, LO ;
Nilsson, P ;
Thomsen, P .
BIOMATERIALS, 1997, 18 (14) :969-978
[3]  
Buser D, 1998, INT J ORAL MAX IMPL, V13, P611
[4]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[5]  
Clokie C M, 1995, Int J Oral Maxillofac Implants, V10, P155
[6]   Biologic determinants of bone formation for osseointegration: Clues for future clinical improvements [J].
Cooper, LF .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (04) :439-449
[7]   ANCHORAGE OF TIO2-BLASTED, HA-COATED, AND MACHINED IMPLANTS - AN EXPERIMENTAL-STUDY WITH RABBITS [J].
GOTFREDSEN, K ;
WENNERBERG, A ;
JOHANSSON, C ;
SKOVGAARD, LT ;
HJORTINGHANSEN, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (10) :1223-1231
[8]  
Gotfredsen K, 1992, Clin Oral Implants Res, V3, P77, DOI 10.1034/j.1600-0501.1992.030205.x
[9]   The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model [J].
Hansson, S ;
Norton, M .
JOURNAL OF BIOMECHANICS, 1999, 32 (08) :829-836
[10]  
LINDER L, 1989, ACTA ORTHOP SCAND, V60, P129