The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning. Magn Reson Med 53:1228-1233, 2005. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1228 / 1233
页数:6
相关论文
共 23 条
[11]   Polar sampling in k-space: Reconstruction effects [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (05) :769-782
[12]   Effects of polar sampling in k-space [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :940-949
[13]   Flow effects in balanced steady state free precession imaging [J].
Markl, M ;
Alley, MT ;
Elkins, CJ ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :892-903
[14]  
Peters DC, 2000, MAGNET RESON MED, V43, P91, DOI 10.1002/(SICI)1522-2594(200001)43:1<91::AID-MRM11>3.0.CO
[15]  
2-4
[16]   Noninvasive comprehensive characterization of renal artery stenosis by combination of STAR angiography and EPISTAR perfusion imaging [J].
Prasad, PV ;
Kim, D ;
Kaiser, AM ;
Chavez, D ;
Gladstone, S ;
Li, W ;
Buxton, RB ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :776-787
[17]  
Spuentrup E, 2003, ROFO-FORTSCHR RONTG, V175, P1330
[18]   Renal arteries:: Navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling:: Initial experience [J].
Spuentrup, E ;
Manning, WJ ;
Börnert, P ;
Kissinger, KV ;
Botnar, RM ;
Stuber, M .
RADIOLOGY, 2002, 225 (02) :589-596
[19]   Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography [J].
Spuentrup, E ;
Börnert, P ;
Botnar, RM ;
Groen, JP ;
Manning, WJ ;
Stuber, M .
INVESTIGATIVE RADIOLOGY, 2002, 37 (11) :637-642
[20]   Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography [J].
Stuber, M ;
Botnar, RM ;
Danias, PG ;
Sodickson, DK ;
Kissinger, KV ;
Van Cauteren, M ;
De Becker, J ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) :524-531