Laryngo-pharyngeal complaints after use of the laryngeal mask airway

被引:47
作者
Figueredo, E
Vivar-Diago, M
Muñoz-Blanco, F
机构
[1] Torrecardenas Hosp, Dept Anaesthesia, Almeria, Spain
[2] Cruz Roja Hosp, Dept Anaesthesia, Almeria, Spain
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1999年 / 46卷 / 03期
关键词
D O I
10.1007/BF03012599
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: To compare the incidence of dysphagia, dysphonia and sore throat following anesthesia, using the laryngeal mask airway (LMA), among patients receiving intermittent positive-pressure ventilation (IPPV) and those breathing spontaneously (SV) and with two different concentrations of nitrous oxide (N2O) in oxygen. Methods: In a prospective trial, 120 patients (ASA I-III, 16-70 yr, > 60 kg) undergoing minor peripheral surgery were randomised into four groups with respect to type of ventilation and N2O concentratjon (50% or 66%) received; Cuff pressure measurements were monitored continuously Twenty-four hours after surgery, patients were questioned for sore throat, dysphagia and dysphonia. Results: At 30 min post-LMA insertion, increases in cuff pressure were 35.2 +/- 17.1 mmHg (22.8%) vs 50.1 +/- 16.3 mmHg (32.7%) in patients breathing 50 and 66% N2O, respectively (P < 0.001), There were no differences in cuff pressure increment between patients in the SV and lPPV groups. Cuff pressure values at the end of surgery depended on the duration of surgery and on the concentrations of N2O. The overall incidence of postoperative discomfort at 24 hr was dysphagia 11%, dysphonia 11% and sore throat 28.8%. Only two patients reported sore throat as more than mild. There was no relationship between cuff pressure and laryngo-pharyngeal complaints. The incidence of dysphonia in the groups receiving IPPV was higher than that in the groups with spontaneous ven tilation (17.2 vs 5%, P < 0,05). Conclusion: Post-operative discomfort is related to the type of ventilation but not to variation in LMA cuff pressure.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 25 条
[1]   Appropriate size and inflation of the laryngeal mask airway [J].
Asai, T ;
Howell, TK ;
Koga, K ;
Morris, S .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (04) :470-474
[2]   Pressure in laryngeal mask airway cuffs [J].
Brain, AIJ .
ANAESTHESIA, 1996, 51 (06) :603-603
[3]   LARYNGEAL MASK MISPLACEMENT - CAUSES, CONSEQUENCES AND SOLUTIONS [J].
BRAIN, AIJ .
ANAESTHESIA, 1992, 47 (06) :531-532
[4]   INSERTION OF THE LARYNGEAL MASK AIRWAY - A PROSPECTIVE-STUDY OF 4 TECHNIQUES [J].
BRIMACOMBE, J ;
BERRY, A .
ANAESTHESIA AND INTENSIVE CARE, 1993, 21 (01) :89-92
[5]   LARYNGEAL MASK AIRWAY CUFF PRESSURE AND POSITION DURING ANESTHESIA LASTING ONE TO 2 HOURS [J].
BRIMACOMBE, J ;
BERRY, A .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (07) :589-593
[6]   The effect of laryngeal mask cuff pressure on postoperative sore throat incidence [J].
Burgard, G ;
Mollhoff, T ;
Prien, T .
JOURNAL OF CLINICAL ANESTHESIA, 1996, 8 (03) :198-201
[7]  
CORK RC, 1994, ANESTH ANALG, V79, P719
[8]  
DINGLEY J, 1994, ANAESTHESIA, V49, P251
[9]   SOLUBILITY OF VOLATILE ANESTHETICS IN SILICONE-RUBBER [J].
FIELDING, R ;
SALAMONSEN, RF .
JOURNAL OF MEMBRANE SCIENCE, 1979, 5 (03) :319-326
[10]  
Figueredo E, 1998, Rev Esp Anestesiol Reanim, V45, P209