Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance

被引:23
作者
Elkington, AG
He, TG
Gatehouse, PD
Prasad, SK
Firmin, DN
Pennell, DJ
机构
[1] Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
[2] Harefield Hosp, NHS Trust, London, England
[3] Univ London Imperial Coll Sci Technol & Med, London, England
关键词
perfusion; cardiovascular magnetic resonance; arterial input function; contrast agent; T1; measurement;
D O I
10.1002/jmri.20294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine how injection rate, cardiac function, and breathhold influence the arterial input function (AIF), in order to optimize the AIF in the clinical setting for quantitative myocardial perfusion cardiovascular magnetic resonance (CMR). Materials and Methods: Gd (0.1 mmol/kg) bolus was injected at 3, 5, or 7 mL/second in 35 patients. In each cardiac cycle during the first-pass, a series of saturation recovery (SR) fast low-angle shot (FLASH) low resolution images with exponentially increasing SR delay times were acquired. Signal intensity (SI) time measurements were made from a region of interest (ROI) drawn in the ascending aorta (AA). The calculation of short T1s and thus peak Gd concentration [Gd] was performed by fitting the mean ROI SI against SR delay times. Results: The mean peak [Gd] in the AA increased as injection rate increased from 3 mL/second (5.0 mM), to 5 mL/1; second (7.1 mM), to 7 mL/second (4 mM) (P < 0.0001). The peak [Gd] increased as the left ventricular stroke volume (LV SV) increased (P = 0.01). Breath holding was not found to influence peak [Gd]. Conclusion: In this study, we found that a high injection rate has advantages over lower injection speeds, although the duration of the AIF was apparently not significantly shortened by faster injection. The choice of expiration or inspiration as breathhold did not have a significant influence upon the AIF. Poor cardiac function was associated with a lower peak [Gd], indicating that first pass perfusion measurements in these patients will be suboptimal. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 16 条
[1]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[2]   INFLUENCE OF BOLUS VOLUME AND DOSE OF GADOLINIUM CHELATE FOR FIRST-PASS MYOCARDIAL PERFUSION MR-IMAGING STUDIES [J].
CANET, E ;
DOUEK, P ;
JANIER, M ;
BENDID, K ;
AMAYA, J ;
MILLET, P ;
REVEL, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :411-415
[3]  
CHRISTIAN T, 2002, P SOC CARD MAGN RES, P160
[4]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[5]   Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance [J].
Gatehouse, PD ;
Elkington, AG ;
Ablitt, NA ;
Yang, GZ ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :39-45
[6]  
HE T, 2004, P 12 ANN M ISMRM KYO
[7]   Noninfarcted myocardium: Correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography [J].
Ishida, N ;
Sukuma, H ;
Motoyasu, M ;
Okinaka, T ;
Isaka, N ;
Nakano, T ;
Takeda, K .
RADIOLOGY, 2003, 229 (01) :209-216
[8]  
IVANCEVIC MK, 2004, P SOC CARD MAGN RES, P294
[9]   Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution [J].
Jerosch-Herold, M ;
Wilke, N ;
Stillman, AE ;
Wilson, RF .
MEDICAL PHYSICS, 1998, 25 (01) :73-84
[10]   Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography [J].
Kopka, L ;
Vosshenrich, R ;
Rodenwaldt, J ;
Grabbe, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :345-348