Pro/con clinical debate: High-frequency oscillatory ventilation is better than conventional ventilation for premature infants

被引:8
作者
Courtney, SE [1 ]
Durand, DJ
Asselin, JM
Eichenwald, EC
Stark, AR
机构
[1] Schneider Childrens Hosp, N Shore Long Isl Jewish Hlth Syst, Div Neonatol, New Hyde Pk, NY 11040 USA
[2] Childrens Hosp Oakland, Div Neonatol, Oakland, CA USA
[3] Childrens Hosp Oakland, Neonatal Pediat Res Grp, Oakland, CA USA
[4] Brigham & Womens Hosp, Neonatal Intens Care Unit, Boston, MA 02115 USA
[5] Harvard Univ, Sch Med, Boston, MA USA
来源
CRITICAL CARE | 2003年 / 7卷 / 06期
关键词
bronchopulmonary dysplasia; high-frequency oscillation; lung injury; mechanical ventilation; respiratory distress; surfactant deficiency;
D O I
10.1186/cc2178
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Arguably one of the most important advances in critical care medicine in recent years has been the understanding that mechanical ventilators can impart harm and that lung-protective ventilation strategies can save lives. High-frequency oscillatory ventilation appears ideally suited for lung protection at first glance. Two camps of opinion exist, however, even in neonates where this modality has been most extensively studied. In the present debate, the prevailing arguments from each of those camps are made available for the reader to decide.
引用
收藏
页码:423 / 426
页数:4
相关论文
共 27 条
[1]   INCREASED MORTALITY OF PRETERM INFANTS TRANSFERRED BETWEEN TERTIARY PERINATAL CENTERS [J].
BOWMAN, E ;
DOYLE, LW ;
MURTON, LJ ;
ROY, RND ;
KITCHEN, WH .
BRITISH MEDICAL JOURNAL, 1988, 297 (6656) :1098-1100
[2]  
CLARK RH, 1992, PEDIATRICS, V89, P5
[3]   Neonatal chronic lung disease in extremely immature baboons [J].
Coalson, JJ ;
Winter, VT ;
Siler-Khodr, T ;
Yoder, BA .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (04) :1333-1346
[4]   High-frequency oscillatory ventilation versus conventional mechanical ventilation for very-low-birth-weight infants [J].
Courtney, SE ;
Durand, DJ ;
Asselin, JM ;
Hudak, ML ;
Aschner, JL ;
Shoemaker, CT .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (09) :643-652
[5]   VENTILATORY MANAGEMENT OF INFANT BABOONS WITH HYALINE-MEMBRANE DISEASE - THE USE OF HIGH-FREQUENCY VENTILATION [J].
DELEMOS, RA ;
COALSON, JJ ;
GERSTMANN, DR ;
NULL, DM ;
ACKERMAN, NB ;
ESCOBEDO, MB ;
ROBOTHAM, JL ;
KUEHL, TJ .
PEDIATRIC RESEARCH, 1987, 21 (06) :594-602
[6]   OPTIMIZING ALVEOLAR EXPANSION PROLONGS THE EFFECTIVENESS OF EXOGENOUS SURFACTANT THERAPY IN THE ADULT-RABBIT [J].
FROESE, AB ;
MCCULLOCH, PR ;
SUGIURA, M ;
VACLAVIK, S ;
POSSMAYER, F ;
MOLLER, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (03) :569-577
[7]  
Gerstmann DR, 1996, PEDIATRICS, V98, P1044
[8]   Childhood outcome after early high-frequency oscillatory ventilation for neonatal respiratory distress syndrome [J].
Gerstmann, DR ;
Wood, K ;
Miller, A ;
Steffen, M ;
Ogden, B ;
Stoddard, RA ;
Minton, SD .
PEDIATRICS, 2001, 108 (03) :617-623
[9]   COMPARISON OF CONVENTIONAL AND HIGH-FREQUENCY VENTILATION - OXYGENATION AND LUNG PATHOLOGY [J].
HAMILTON, PP ;
ONAYEMI, A ;
SMYTH, JA ;
GILLAN, JE ;
CUTZ, E ;
FROESE, AB ;
BRYAN, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (01) :131-138
[10]   Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators [J].
Hatcher, D ;
Watanabe, H ;
Ashbury, T ;
Vincent, S ;
Fisher, J ;
Froese, A .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1081-1088