Quantitative analysis of anions at ppb/ppt levels with capillary electrophoresis and conductivity detection: Enhancement of system linearity and precision using an internal standard

被引:46
作者
Haber, C
VanSaun, RJ
Jones, WR
机构
[1] Or Res, Beverly, MA 01915 USA
[2] Thermo Bioanal, Franklin, MA 02038 USA
关键词
D O I
10.1021/ac9712106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis with conductivity detection is evaluated for quantitative analysis of anions at low-to sub-ppb concentration levels in the presence and absence of a conductive sample matrix composed of 2 ppm ammonia and 50 ppb hydrazine. The low-level sensitivity is extended by a transient isotachophoretic stacking procedure. The linear range of the CE system and conductivity detector is graphically evaluated on the basis of absolute and corrected (normalized) chloride and sulfate peak profiles using an ASTM linearity criterion. The influence of random contamination bias from ubiquitous entities of nonsample chloride and sulfate levels introduced by liquid handling, laboratory atmosphere, and bulk chemical residues is quantitatively compared against an internal (contamination) reference ion.
引用
收藏
页码:2261 / 2267
页数:7
相关论文
共 33 条
[1]  
*AM SOC TEST MAT, 1988, ANN BOOK ASTM STAND, P149
[2]   ISOTACHOPHORESIS WITH 2 LEADING IONS AND MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS .2. MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :19-26
[3]   APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS WITH AN ISOTACHOPHORETIC INITIAL-STATE TO DETERMINE ANIONIC IMPURITIES ON AS-POLISHED SILICON-WAFER SURFACES [J].
BODEN, J ;
BACHMANN, K ;
KOTZ, L ;
FABRY, L ;
PAHLKE, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (02) :321-332
[4]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[5]   DETERMINATION OF BORON AND PHOSPHORUS IN BOROPHOSPHOSILICATE THIN-FILMS ON SILICON SUBSTRATES BY CAPILLARY ELECTROPHORESIS [J].
CARPIO, RA ;
MARISCAL, R ;
WELCH, J .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2123-2129
[6]   ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
HELMER, JC .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1354-1361
[7]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[8]  
COLIN H, 1986, PRACTICE HIGH PERFOR, P31
[9]  
DOLNIK V, 1990, J MICROCOLUMN SEP, V2, P127
[10]   LC DETECTORS - EVALUATION AND PRACTICAL IMPLICATIONS OF LINEARITY [J].
DORSCHEL, CA ;
EKMANIS, JL ;
OBERHOLTZER, JE ;
WARREN, FV ;
BIDLINGMEYER, BA .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :A951-&