Application of inductively coupled plasma sector field mass spectrometry for the fast and sensitive determination and isotope ratio measurement of non-metals in high-purity process chemicals

被引:42
作者
Wildner, H [1 ]
机构
[1] UKAEA, Technol, Analyt Serv Grp, Harwell OX11 0RA, Berks, England
关键词
inductively coupled plasma sector field mass spectrometry; non-metals; high resolution; isotope ratios;
D O I
10.1039/a708922h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of non-metals (e.g., Si, P, S, Cl, As, Se and Br) by convenient quadrupole ICP-MS systems is extremely difficult owing to the presence of molecular spectral interferences from H, C, N, O and Ar and the high ionisation energies of these elements (8-13 eV). Therefore, the determination of anion forming elements is the domain of ion chromatography. Since this is a very time-consuming technique giving no isotopic information, the use of inductively coupled plasma sector field mass spectrometry (ICP-SFMS) was studied, By applying medium or high resolution from 3000 for Si and P to 12000 for Se, the background can be lowered by up to five orders of magnitude, resulting in limits of detection between 1 pg g(-1) for As (high purity mater without dilution) and 2 mu g g(-1) for Cl (e.g., in H2SO4 after 25-fold dilution) in routine analysis and multi-element mode. Ionisation rates were found to be between 0.5% for Cl and 50% for Si, These rates can be improved by using a dried aerosol obtainable by an ultrasonic or microconcentric nebuliser, However, this does not always lead to higher sensitivity because these elements are lost in the desolvation stage at a rate between 50 and 90%. Nevertheless, the spectral interferences are lowered. Isotope ratios for Si, S, Cl, Se and Br are obtainable with a precision of 0.5-3%, allowing quantification by isotope dilution.
引用
收藏
页码:573 / 578
页数:6
相关论文
共 18 条
[1]   Double-focusing sector field inductively coupled plasma mass spectrometry for highly sensitive multi-element and isotopic analysis - Invited lecture [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :881-889
[2]   Trace element determination of high-purity chemicals for the processing of semiconductors with high-resolution ICP mass spectrometry using stable isotope dilution analysis (IDA) [J].
Dahmen, J ;
Pfluger, M ;
Martin, M ;
Rottmann, L ;
Weichbrodt, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :410-413
[3]   Plasma spectrometry and molecular information [J].
Donard, OFX ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :871-876
[4]  
Houk R., 1986, ANAL CHEM, V58, P97
[5]   CHARACTERIZATION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING A HIGH-RESOLUTION MASS-SPECTROMETER [J].
REED, NM ;
CAIRNS, RO ;
HUTTON, RC ;
TAKAKU, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) :881-896
[6]   Determination of trace and ultratrace elements in human serum with a double focusing magnetic sector inductively coupled plasma mass spectrometer [J].
Riondato, J ;
Vanhaecke, F ;
Moens, L ;
Dams, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :933-937
[7]  
RUTH K, 1992, SPECTROSCOPY, V7, P36
[8]   ONLINE COUPLING BETWEEN CHROMATOGRAPHY AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - A CURRENT ASSESSMENT [J].
SEUBERT, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (4-5) :210-220
[9]   Measurements of Ca-44:Ca-43 and Ca-42:Ca-43 isotopic ratios in urine using high resolution inductively coupled plasma mass spectrometry [J].
Sturup, S ;
Hansen, M ;
Molgaard, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :919-923
[10]   DETERMINATION OF TRACE SILICON IN ULTRA-HIGH-PURITY WATER BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
TAKAKU, Y ;
MASUDA, K ;
TAKAHASHI, T ;
SHIMAMURA, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1385-1387