Stress and strain distribution within the intact femur: Compression or bending

被引:188
作者
Taylor, ME
Tanner, KE
Freeman, MAR
Yettram, AL
机构
[1] ROYAL LONDON HOSP,COLL MED,LONDON,ENGLAND
[2] BRUNEL UNIV,DEPT MECH ENGN,UXBRIDGE UB8 3PH,MIDDX,ENGLAND
关键词
stress and strain distribution; intact femur; compression bending;
D O I
10.1016/1350-4533(95)00031-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite element analysis of the intact femur to assess if a compressive stress distribution could be achieved in the diaphyseal region of the femur using physiological muscle and joint contact forces; a simple radiological study to assess the in vivo deflections of the femur during one legged stance. The results of this investigation strongly support the hypothesis that the femur is loaded primarily in compression, and not bending as previously thought. The finite element analysis demonstrated that a compressive stress distribution in the diaphyseal femur can be achieved, producing a stress distribution which appears to be consistent with the femoral cross-sectional geometry. The finite element analysis also predicted that for a compressive load case there would be negligible deflections of the femoral head. The radiological study confirmed this, with no measurable in vivo deflection of the femur occurring during one legged stance.
引用
收藏
页码:122 / 131
页数:10
相关论文
共 24 条
  • [1] [Anonymous], MECH PROP BONE
  • [2] [Anonymous], 1986, LAW BONE REMODELLING
  • [3] A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE
    ASHMAN, RB
    COWIN, SC
    VANBUSKIRK, WC
    RICE, JC
    [J]. JOURNAL OF BIOMECHANICS, 1984, 17 (05) : 349 - 361
  • [4] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [5] ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY
    CHEAL, EJ
    SPECTOR, M
    HAYES, WC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) : 405 - 422
  • [6] BIOMECHANICAL INVESTIGATION OF HUMAN HIP
    CROWNINSHIELD, RD
    JOHNSTON, RC
    ANDREWS, JG
    BRAND, RA
    [J]. JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) : 75 - 85
  • [7] CURREY JD, 1984, MECH ADAPTION BONES
  • [8] TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY
    DAVY, DT
    KOTZAR, GM
    BROWN, RH
    HEIPLE, KG
    GOLDBERG, VM
    HEIPLE, KG
    BERILLA, J
    BURSTEIN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) : 45 - 50
  • [9] FROST HM, 1973, ORTH LECT SPRINGF
  • [10] HUISKES R, 1990, CLIN ORTHOPAEDICS, V261, P27