Contrast-specific ultrasonic flow measurements based on both input and output time intensities

被引:20
作者
Yeh, CK
Yang, MJ
Li, PC
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 106, Taiwan
[2] Natl Hlth Res Inst, Div Med Engn Res, Taipei, Taiwan
关键词
flow estimation; indicator-dilution theory; shadowing effect; time-intensity curve; ultrasonic contrast agent;
D O I
10.1016/S0301-5629(02)00771-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic contrast agents are used to assess perfusion conditions based on evaluation of the time-intensity curve. Such a curve reflects the concentration of microbubbles in the perfused area and the indicator-dilution theory is used to derive the volumetric flow rate from the measured concentration. Previous results have shown that the technique is not reliable in some conditions due to the shadowing effect. To overcome this problem, a contrast-specific technique using both the input and output time-intensity relationships is proposed; this contrasts with conventional techniques that utilize only the relationship directly from the perfused area. The proposed technique is referred to as the input-output time-intensity curve (IOTIC) method. In this work, the shadowing effect was studied experimentally and the efficacy of the IOTIC technique was assessed and compared with conventional techniques. The results indicate that the IOTIC technique eliminates the shadowing effect and provides a good correlation between the actual flow rate and measured flow-related parameters; thus, making quantitative estimation of perfusion feasible. Note that the IOTIC is applicable, based on the assumption that both the input and the output can be positioned within the same image plane; its clinical applications include situations where the perfused area cannot be effectively imaged by ultrasound (US). One example is the assessment of brain perfusions and it will be used as a target clinical application of the IOTIC technique. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:671 / 678
页数:8
相关论文
共 21 条
[1]   Effects of shadowing on the time-intensity curves in contrast echocardiography: A phantom study [J].
Bos, LJ ;
Piek, JJ ;
Spaan, JAE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (02) :217-227
[2]  
CHANG PH, 1993, IEEE ULTRASONICS S P, V2, P913
[3]   A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography [J].
Chen, XC ;
Schwarz, KQ ;
Phillips, D ;
Steinmetz, SD ;
Schlief, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) :754-765
[4]   Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study [J].
Claassen, L ;
Seidel, G ;
Algermissen, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :83-88
[5]  
Cooney DO., 1976, BIOMEDICAL ENG PRINC
[6]  
DSA A, 1999, ACOUSTIC DENSITOMETR
[7]  
GOLDBERG BB, 1997, ULTRASOUND CONTRAST, P27
[8]  
Heidenreich P A, 1993, J Am Soc Echocardiogr, V6, P51
[9]   MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY AND THE TRANSMURAL DISTRIBUTION OF FLOW - A CRITICAL-APPRAISAL DURING MYOCARDIAL-ISCHEMIA NOT ASSOCIATED WITH INFARCTION [J].
KAUL, S ;
JAYAWEERA, AR ;
GLASHEEN, WP ;
VILLANUEVA, FS ;
GUTGESELL, HP ;
SPOTNITZ, WD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :1005-1016
[10]   Time-intensity-based volumetric flow measurements:: An in vitro study [J].
Li, PC ;
Yeh, CK ;
Wang, SW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03) :349-358