Automatic model-based contour detection and blood flow quantification in small vessels with velocity encoded magnetic resonance imaging

被引:22
作者
Box, FMA
Spilt, A
Van Buchem, MA
van der Geest, RJ
Reiber, JHC
机构
[1] Leiden Univ, Ctr Med, Dept Radiol, Div Image Proc, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Ctr Med, Dept Radiol, NL-2300 RC Leiden, Netherlands
关键词
magnetic resonance imaging; blood flow; flow volume; modeling; image processing;
D O I
10.1097/01.RLI.0000077125.58014.36
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The quantitative assessment of blood flow in peripheral vessels from phase-contrast magnetic resonance imaging studies requires the accurate delineation of vessel contours in cross-sectional magnetic resonance images. The conventional manual segmentation approach is tedious, time-consuming, and leads to significant inter- and intraobserver variabilities. The aim of this study was to verify whether automatic model-based segmentation decreases these problems by fitting a model to the actual blood velocity profile. Methods: In this study 2 new fully automatic methods (a static and a dynamic approach) were developed and compared with manual analyzes using phantom and in vivo studies of internal carotid and vertebral arteries in healthy volunteers. The automatic segmentation approaches were based on fitting a 3D parabolic velocity model to the actual velocity profiles. In the static method, the velocity profiles were averaged over the complete cardiac cycle, whereas the dynamic method takes into account the velocity data of each cardiac time bin individually. Materials consisted of the magnetic resonance imaging data from 3 straight phantom tubes and the blood velocity profiles of 8 volunteers. Results: For the phantom studies, the automatic dynamic approach performed significantly better than the manual analysis (intraclass correlations [ICC] of 0.62-0.98 and 0.30-0.86, respectively). For the assessment of the total cerebral blood flow in the in vivo studies, the automatic static method performed significantly better than the manual I (ICC of 0.98-0.98 and 0.93-0.95, respectively). However, the automatic dynamic method was not significantly better than the manual I (ICC=0.92-0.96) but had the advantage of providing additional parameters. Conclusion: Blood flow in magnetic resonance images of small vessels can be assessed accurately, rapidly, and fully automatically using model-based postprocessing by fitting a first approximation of the velocity profile to the actual flow data.
引用
收藏
页码:567 / 577
页数:11
相关论文
共 20 条
[1]  
BOX FMA, 1999, P ISMRM, V7, P571
[2]   Effect of age on cerebral blood flow: Measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults [J].
Buijs, PC ;
Krabbe-Hartkamp, MJ ;
Bakker, CJG ;
de Lange, EE ;
Ramos, LMP ;
Breteler, MMB ;
Mali, WPTM .
RADIOLOGY, 1998, 209 (03) :667-674
[3]   CINE PHASE-CONTRAST MR FLOW MEASUREMENTS - IMPROVED PRECISION USING AN AUTOMATED-METHOD OF VESSEL DETECTION [J].
BURKART, DJ ;
FELMLEE, JP ;
JOHNSON, CD ;
WOLF, RL ;
WEAVER, AL ;
EHMAN, RL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (03) :469-475
[4]   Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping [J].
Davis, CP ;
Liu, PF ;
Hauser, M ;
Gohde, SC ;
vonSchulthess, GK ;
Debatin, JF .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :537-544
[5]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[6]   Streamlined flow in the portal vein: Demonstration with MR angiography [J].
Gallix, BP ;
Reinhold, C ;
Dauzat, M ;
Bret, PM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :603-609
[7]  
GEEST VDJ, 1998, J COMPUT ASSIST TOMO, V22, P904
[8]   Association between intima-media thickness and wall shear stress in common carotid arteries in healthy male subjects [J].
Gnasso, A ;
Carallo, C ;
Irace, C ;
Spagnuolo, V ;
DeNovara, G ;
Mattioli, PL ;
Pujia, A .
CIRCULATION, 1996, 94 (12) :3257-3262
[9]  
Hoogeveen RM, 1999, MAGNET RESON MED, V41, P520, DOI 10.1002/(SICI)1522-2594(199903)41:3<520::AID-MRM14>3.0.CO
[10]  
2-A