Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds

被引:48
作者
Kristenson, EM
Korytár, P
Danielsson, C
Kallio, M
Brandt, M
Mäkelä, J
机构
[1] Vrije Univ Amsterdam, Fac Sci, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
[2] Netherlands Inst Fishery Res, RIVO, NL-1970 AB Ijmuiden, Netherlands
[3] Umea Univ, S-90187 Umea, Sweden
[4] Univ Helsinki, Dept Chem, Analyt Chem Lab, Helsinki 00014, Finland
关键词
modulators; electron-capture detector; gas chromatography; comprehensive two-dimensional;
D O I
10.1016/S0021-9673(03)01237-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different cryogenic and a heated GC x GC modulator(s) were evaluated and compared for the analysis of high-boiling halogenated compounds. The cryogenic modulators investigated were: (i) the longitudinally modulated cryogenic system; (ii) the liquid- nitrogen-cooled jet modulator (KT2001); (iii) a dual-jet CO, modulator (made in-house); (iv) a semi-rotating cryogenic modulator (made in-house) and (v) a CO2 loop modulator (KT2003); the heated modulator was the slotted heater system (sweeper). Each modulator was optimised with respect to analyte peak widths at half height in the second-dimension. n-Alkanes, chlorinated alkanes, polychlorinated biphenyls (PCBs) and fluorinated polycyclic aromatic hydrocarbons (F-PAHs) were used as test analytes. The flow rate of the coolant was found to be an important parameter, i.e. the flow rate of the gaseous nitrogen in the KT2001, and of the liquid CO2 in the other cryogenic modulators. For the slotted heater the stroke velocity and pause time were important parameters. This modulator had a limited application range in terms of temperature due to a necessary 100degreesC difference between sweeper and oven temperature. All cryogenic modulators were found to be suitable for the GC x GC analysis of hi.-h-boiling compounds, but the CO, modulators are to be preferred to the KT2001 due to a wider application range and slightly narrower peaks. As regards the performance of three commercially available electron-capture detectors (ECDs), the aim was to obtain narrow peak widths in GC x GC, i.e. to avoid band broadening caused by the cell volume. The most important parameters were the flow rate of the make-up gas and the detector temperature which both should be as high as possible. Comparison of analyte peak widths obtained with ECD mode and flame ionisation detection (FID) showed that all ECDs exhibited band broadening compared to the FID. The narrowest peaks were obtained with the Agilent micro-ECD, which has a cell volume of only 150 mul. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 77
页数:13
相关论文
共 36 条
[1]   Single-jet, single-stage cryogenic modulator for comprehensive two-dimensional gas chromatography (GC x GC) [J].
Adahchour, M ;
Beens, J ;
Brinkman, UAT .
ANALYST, 2003, 128 (03) :213-216
[2]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[3]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[4]  
Blomberg J, 1997, HRC-J HIGH RES CHROM, V20, P539
[5]   Comprehensive two-dimensional gas chromatograpy with time-of-flight mass spectrometric detection applied to the determination of pesticides in food extracts [J].
Dallüge, J ;
van Rijn, M ;
Beens, J ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :207-217
[6]   Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool [J].
Dallüge, J ;
Beens, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :69-108
[7]  
de Geus HJ, 2000, HRC-J HIGH RES CHROM, V23, P189
[8]   Comprehensive gas chromatography of high-boiling halogenated compounds [J].
de Geus, HJ ;
de Boer, J ;
Brinkman, UAT .
CHROMATOGRAPHIA, 2002, 55 (5-6) :339-344
[9]  
Frysinger GS, 1999, HRC-J HIGH RES CHROM, V22, P195
[10]   Effects of temperature and flow regulated carbon dioxide cooling in longitudinally modulated cryogenic systems for comprehensive two-dimensional gas chromatography [J].
Haglund, P ;
Harju, M ;
Danielsson, C ;
Marriott, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 962 (1-2) :127-134