Multi-elemental speciation studies of trace elements associated with metallothionein-like proteins in mussels by liquid chromatography with inductively coupled plasma time-of-flight mass spectrometric detection

被引:41
作者
Ferrarello, CN [1 ]
Bayón, MM [1 ]
de la Campa, RF [1 ]
Sanz-Medel, A [1 ]
机构
[1] Fac Chem, Dept Phys & Analyt Chem, Oviedo 33006, Spain
关键词
D O I
10.1039/b005080f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of complementary chromatographic separations such as size exclusion (SEC) plus anion-exchange chromatography coupled with Inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS), uas evaluated for the multi-elemental speciation of trace elements associated with methallothionein-like proteins (MLPs) in mussel hepatopancreas. The initial separation of the proteins is performed by "off-line" SEC, collecting fractions; which are then analysed for the trace elements by ICP-TOF-MS in small sample volumes. Further purification is accomplished by the separation of the different proteins contained in the above obtained MLP fraction on a Mono Q (HR 5/5) anion-exchange column [fast protein liquid chromatography (FPLC)], using an ammonium acetate gradient at a physiological pH of 7.4 as the mobile phase. The separated proteins are detected "on-line" by UV absorption at 254 and 280 nm. Specific detection (16 metals) with on-line ICP-TOF-MS was also performed. This hybrid approach was applied to investigate the metal binding patterns of the proteins expressed by mussels which had been previously exposed to 16 trace metals in an aquarium tank for 1 and 2 weeks. The exceptional characteristics of ICP-TOF-MS for quasi-simultaneous monitoring of many trace elements in transient signals are illustrated by this "on-line" coupling to FPLC separation, paving the way to virtually simultaneous multi-elemental speciation of trace metals in biological material.
引用
收藏
页码:1558 / 1563
页数:6
相关论文
共 26 条
[1]   Capabilities of fast protein liquid chromatography coupled to a double focusing inductively coupled plasma mass spectrometer for trace metal speciation in human serum [J].
Bayón, MM ;
Cabezuelo, ABS ;
González, EB ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (06) :947-951
[2]   An alternative GC-ICP-MS interface design for trace element speciation [J].
Bayón, MM ;
Camblor, MG ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1317-1322
[3]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823
[4]  
FERNANDEZ JMC, 2000, J ANAL ATOM SPECTROM, V15, P1063
[5]  
Fernández RG, 2000, J MASS SPECTROM, V35, P639, DOI 10.1002/(SICI)1096-9888(200005)35:5<639::AID-JMS990>3.0.CO
[6]  
2-G
[7]   Improved separation of rabbit liver metallothioneins by FPLC-ICP-MS:: a comparison with the conventional anion-exchange chromatography [J].
Ferrarello, C ;
de la Campa, MRF ;
Infante, HG ;
Sánchez, MLF ;
Sanz-Medel, A .
ANALUSIS, 2000, 28 (05) :351-357
[8]  
FERRARELLO CN, IN PRESS ANAL CHEM
[9]   Gas chromatography-inductively coupled plasma time-of-flight mass spectrometry for the speciation analysis of organometallic compounds [J].
Leach, AM ;
Heisterkamp, M ;
Adams, FC ;
Hieftje, GM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (02) :151-155
[10]   Analysis for metallothioneins using coupled techniques [J].
Lobinski, R ;
Chassaigne, H ;
Szpunar, J .
TALANTA, 1998, 46 (02) :271-289