Gas chromatography-inductively coupled plasma time-of-flight mass spectrometry for the speciation analysis of organometallic compounds

被引:61
作者
Leach, AM [1 ]
Heisterkamp, M
Adams, FC
Hieftje, GM
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Univ Instelling Antwerp, Dept Chem, B-2610 Antwerp, Belgium
关键词
D O I
10.1039/a905825g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inductively coupled plasma time-of-flight mass spectrometer was combined with a capillary gas chromatograph for the speciation analysis of organotin and organolead compounds. The ability to produce complete mass spectra at a high frequency (typically >20 000 mass spectra per second) makes, time-of-flight mass spectrometry nearly ideal for the detection of transient signals such as those produced by high speed chromatographic techniques. In this study, GC-ICP-TOFMS instrumental figures of merit were determined for the separation of tetramethyltin, tetraethyltin and tetraethyllead. Data acquisition speed of the current system was limited to 78 integrated complete mass spectra (255 individual spectra summed) per second. However, because all mass-to-charge ratios are detected, collection of a data point every 12.75 ms is sufficient for the measurement of all but the fastest transient signals (peak widths <50 ms). A tin isotope-ratio accuracy of 0.28% and a precision of 2.88% (RSD) were calculated for a 1 s gas chromatographic peak of tetramethyltin. Limits of detection for all three analytes were found to be in the low femtogram region, with a dynamic range of greater than six orders of magnitude.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 30 条
[1]   Spatial location of the space charge effect in individual ion clouds using monodisperse dried microparticulate injection with a twin quadrupole inductively coupled plasma mass spectrometer [J].
Allen, LA ;
Leach, JJ ;
Houk, RS .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2384-2391
[2]   Precise measurement of ion ratios in solid samples using laser ablation with a twin quadrupole inductively coupled plasma mass spectrometer [J].
Allen, LA ;
Leach, JJ ;
Pang, HM ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :171-176
[3]   SIMULTANEOUS MEASUREMENT OF ISOTOPE RATIOS IN SOLIDS BY LASER-ABLATION WITH A TWIN QUADRUPOLE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER [J].
ALLEN, LA ;
PANG, HM ;
WARREN, AR ;
HOUK, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :267-271
[4]   Design and performance of a plasma-source mass spectrograph [J].
Burgoyne, TW ;
Hieftje, GM ;
Hites, RA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (04) :307-318
[5]   Novel multichannel plasma-source mass spectrometer [J].
Cromwell, EF ;
Arrowsmith, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (05) :458-466
[6]   Capillary electrophoresis: the state-of-the-art in metal speciation studies [J].
Dabek-Zlotorzynska, E ;
Lai, EPC ;
Timerbaev, AR .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :1-26
[7]   Ion traps: What be they hold for elemental mass analysis? [J].
Duckworth, DC ;
Barshick, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :709A-717A
[8]  
EVANS EH, 1995, INDUCTIVELY COUPLED
[9]   OPTIMIZATION OF THE MASS SCANNING RATE FOR THE DETERMINATION OF LEAD ISOTOPE RATIOS USING AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER [J].
FURUTA, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :199-203
[10]   RECENT DEVELOPMENTS IN INDUCTIVELY-COUPLED PLASMA MAGNETIC-SECTOR MULTIPLE COLLECTOR MASS-SPECTROMETRY [J].
HALLIDAY, AN ;
LEE, DC ;
CHRISTENSEN, JN ;
WALDER, AJ ;
FREEDMAN, PA ;
JONES, CE ;
HALL, CM ;
YI, W ;
TEAGLE, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 146 :21-33