Evaluation of respiratory artifact correction techniques in multishot spiral functional MRI using receiver operator characteristic analyses

被引:17
作者
Noll, DC
Genovese, CR
Vazquez, AL
O'Brien, JL
Eddy, WF
机构
[1] Univ Pittsburgh, Med Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Dept Stat, Pittsburgh, PA USA
关键词
functional MRI; receiver operator characteristic; respiration; image artifacts;
D O I
10.1002/mrm.1910400417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Navigator corrections and low-spatial frequency (LSF) over-sampling are investigated as methods for reducing respiration-related effects in multishot functional MRI. Both techniques take advantage of the smoothly varying or nearly constant phase variations linked to the respiration cycle. These techniques were tested in functional MRI studies with spiral k-space acquisitions. Receiver operator characteristic (ROC) analyses and the temporal variance averaged across the brain were used to evaluate their effectiveness. Both methods were found to increase the area under the ROC curve and to reduce the standard deviation, with the LSF oversampling method being more effective.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 37 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[3]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[4]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[5]  
Biswal B., 1993, P SMRM 12 ANN M NEW, P722
[6]   INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
THOMPSON, RM ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :67-72
[7]   ULTRA-FAST IMAGING [J].
COHEN, MS ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :1-37
[8]   3-DIMENSIONAL FUNCTIONAL IMAGING OF HUMAN BRAIN USING ECHO-SHIFTED FLASH MRI [J].
DUYN, JH ;
MATTAY, VS ;
SEXTON, RH ;
SOBERING, GS ;
BARRIOS, FA ;
LIU, GY ;
FRANK, JA ;
WEINBERGER, DR ;
MOONEN, CTW .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :150-155
[9]   Improved image registration by using Fourier interpolation [J].
Eddy, WF ;
Fitzgerald, M ;
Noll, DC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :923-931
[10]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139