Carbon nanotubes-based chemiresistive biosensors for detection of microorganisms

被引:91
作者
Garcia-Aljaro, Cristina [1 ]
Cella, Lakshmi N. [2 ,3 ]
Shirale, Dhamanand J. [2 ]
Park, Miso [2 ]
Javier Munoz, Francisco [1 ]
Yates, Marylynn V. [4 ]
Mulchandani, Ashok [2 ]
机构
[1] Esfera UAB, Inst Microelect Barcelona IMB CNM, CSIC, Bellaterra 08193, Barcelona, Spain
[2] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
[3] Univ Calif Riverside, Cellular Mol & Dev Biol Grad Program, Riverside, CA 92521 USA
[4] Univ Calif Riverside, Dept Environm Sci, Riverside, CA 92521 USA
关键词
Escherichia coli; Virus; Bacteriophage; Biosensor; Carbon nanotube; Pathogen; ESCHERICHIA-COLI; ADSORPTION; RECOGNITION; SURFACES; DNA;
D O I
10.1016/j.bios.2010.07.077
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The paper reports carbon nanotube (CNT)-based immunosensors for the detection of two types of microorganisms, bacteria and viruses. The pathogen Escherichia coli O157:H7 and the bacteriophage T7 were selected as model for bacteria and viruses, respectively, while E. coli K12 and the bacteriophage MS2 were used to assess the selectivity of the biosensor. The transduction element consisted of single-walled carbon nanotubes aligned in parallel bridging two gold electrodes to function as a chemiresistive biosensor. Single-walled carbon nanotubes (SWNTs) were functionalized with specific antibodies (Ab) for the different microorganisms by covalent immobilization to the non-covalently bound 1-pyrene butanoic acid succinimidyl ester. A significant increase in the resistance of the device was observed when the biosensor was exposed to E. coli O157:H7 whole cells or lysates with a limit of detection of 10(5) and 10(3) CFU (colony forming units)/mL, corresponding to 10(3) and 10(1) CFU/chip, respectively, while no response was observed when the biosensor was exposed to the E. coli K12. In the case of virus detection, a significant resistance increase was detected due to interaction of the bacteriophages with the Abs, with a limit of detection of 10(3) PFU/mL corresponding to 10(1) PFU/chip and excellent selectivity against MS2 bacteriophage. The sensor exhibited a fast response time of similar to 5 min in the case of bacteriophage detection, while the response time for the detection of bacteria was 60 min. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1437 / 1441
页数:5
相关论文
共 30 条
[1]  
Adams MH, 1959, BACTERIOPHAGES, DOI 10.5962/bhl.title.6966
[2]   Carbon nanotube field-effect-transistor-based biosensors [J].
Allen, Brett Lee ;
Kichambare, Padmakar D. ;
Star, Alexander .
ADVANCED MATERIALS, 2007, 19 (11) :1439-1451
[3]   Network single-walled carbon nanotube-field effect transistors (SWNT-FETs) with increased Schottky contact area for highly sensitive biosensor applications [J].
Byon, HR ;
Choi, HC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) :2188-2189
[4]   Nano Aptasensor for Protective Antigen Toxin of Anthrax [J].
Cella, Lakshmi N. ;
Sanchez, Pablo ;
Zhong, Wenwan ;
Myung, Nosang V. ;
Chen, Wilfred ;
Mulchandani, Ashok .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :2042-2047
[5]   An investigation of the mechanisms of electronic sensing of protein adsorption on carbon nanotube devices [J].
Chen, RJ ;
Choi, HC ;
Bangsaruntip, S ;
Yenilmez, E ;
Tang, XW ;
Wang, Q ;
Chang, YL ;
Dai, HJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (05) :1563-1568
[6]   Studies on the electrical charge of bacteriophage [J].
Clifton, CE ;
Madison, RR .
JOURNAL OF BACTERIOLOGY, 1931, 22 (04) :255-260
[7]   Immuno-carbon nanotubes and recognition of pathogens [J].
Elkin, T ;
Jiang, XP ;
Taylor, S ;
Lin, Y ;
Gu, LR ;
Yang, H ;
Brown, J ;
Collins, S ;
Sun, YP .
CHEMBIOCHEM, 2005, 6 (04) :640-643
[8]   Real-time PCR in clinical microbiology: Applications for a routine laboratory testing [J].
Espy, MJ ;
Uhl, JR ;
Sloan, LM ;
Buckwalter, SP ;
Jones, MF ;
Vetter, EA ;
Yao, JDC ;
Wengenack, NL ;
Rosenblatt, JE ;
Cockerill, FR ;
Smith, TF .
CLINICAL MICROBIOLOGY REVIEWS, 2006, 19 (01) :165-+
[9]   Surface plasmon resonance assay for real-time monitoring of somatic coliphages in wastewaters [J].
Garcia-Aljaro, Cristina ;
Munoz-Berbel, Xavier ;
Jenkins, A. Toby A. ;
Blanch, Anicet R. ;
Xavier Munoz, Francesc .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (13) :4054-4058
[10]   On-chip impedimetric detection of bacteriophages in dairy samples [J].
Garcia-Aljaro, Cristina ;
Munoz-Berbel, Xavier ;
Munoz, Francisco J. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1712-1716