Surface-induced dissociation of peptides and protein complexes in a quadrupole/Time-of-Flight mass spectrometer

被引:52
作者
Galhena, Asiri S. [1 ]
Dagan, Shai [1 ]
Jones, Christopher M. [1 ]
Beardsley, Richard L. [1 ]
Wysocki, Vicki N. [1 ]
机构
[1] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
关键词
D O I
10.1021/ac701782q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel in-line surface-induced dissociation (SID) device was designed and implemented in a commercial QTOF instrument (Waters/Micromass QTOF 11). This new setup allows efficient SID for a broad range of molecules. It also allows direct comparison with conventional collision-induced dissociation (CID) on the same instrument, taking advantage of the characteristics of QTOF instrumentation, including extended mass range, improved sensitivity, and better resolution compared with quadrupole analyzers and ion traps. Various peptides and a noncovalent protein complex have been electrosprayed and analyzed with the new SID setup. Here we present SID of leucine enkephalin, fibrinopeptide A, melittin, insulin chain-B, and a noncovalent protein complex from wheat, heat shock protein 16.9. The SID spectra were also compared to CID spectra. With the SID setup installed, ion transmission proved to be efficient. SID fragmentation patterns of peptides are, in general, similar to CID, with differences in the relative intensities of some peaks such as immonium ions, backbone cleavage b- versus y-type ions, and y- versus y-NH3 ions, suggesting enhanced accessibility to high-energy/secondary fragmentation channels with SID. Furthermore, these results demonstrate that the in-line SID setup is a valid substitute for CID, with potential advantages for activation of singly/multiply charged peptides and larger species such as noncovalent protein complexes.
引用
收藏
页码:1425 / 1436
页数:12
相关论文
共 75 条
[21]   COLLISIONS OF POLYATOMIC IONS WITH SURFACES [J].
COOKS, RG ;
AST, T ;
MABUD, A .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1990, 100 :209-265
[22]   SURFACE MODIFIED MASS-SPECTROMETRY [J].
COOKS, RG ;
TERWILLIGER, DT ;
AST, T ;
BEYNON, JH ;
KEOUGH, T .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1975, 97 (06) :1583-1585
[23]   Role of the site of protonation in the low-energy decompositions of gas phase peptide ions (vol 7, pg 522, 1996) [J].
Cox, KA ;
Gaskell, SJ ;
Morris, M ;
Whiting, A .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (08) :759-759
[24]  
Dahl D.A., 2000, SIMION 3D VERSION 7
[25]   STUDIES OF THE MECHANISM OF COLLISION-INDUCED DISSOCIATION AT LOW ENERGIES USING A TRIPLE QUADRUPOLE [J].
DAWSON, PH ;
DOUGLAS, DJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 47 (JAN) :121-124
[26]   ENERGY DEPOSITION IN [FE(CO)5]+. UPON COLLISION WITH A METAL-SURFACE [J].
DEKREY, MJ ;
KENTTAMAA, HI ;
WYSOCKI, VH ;
COOKS, RG .
ORGANIC MASS SPECTROMETRY, 1986, 21 (04) :193-195
[27]   THE EFFECT OF COLLISION ENERGY AND NATURE OF THE SURFACE ON THE SURFACE-INDUCED DISSOCIATION MASS-SPECTRA OF FLUOROBENZENE USING A 4-SECTOR MASS-SPECTROMETER [J].
DESPEYROUX, D ;
WRIGHT, AD ;
JENNINGS, KR ;
EVANS, S ;
RIDDOCH, A .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 122 :133-141
[28]  
Dongre AR, 1996, J MASS SPECTROM, V31, P339
[29]  
DONGRE AR, 1994, ABSTR PAP AM CHEM S, V208
[30]   Characterization of a new in-line SID mode and comparison with high energy CID [J].
Durkin, DA ;
Schey, KL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 174 (1-3) :63-71