Frequency Adaptive PLL for Polluted Single-Phase Grids

被引:88
作者
Carugati, Ignacio [1 ]
Donato, Patricio [1 ]
Maestri, Sebastian [1 ]
Carrica, Daniel [1 ]
Benedetti, Mario [1 ]
机构
[1] Univ Nacl Mar del Plata, Lab Instrumentac & Control, Fac Ingn, RA-7600 Mar Del Plata, Argentina
关键词
Phase-locked loops (PLLs); phase synchronization; single-phase system; sliding Goertzel transform (SGT); LOCKED LOOP SYSTEM; POWER; SYNCHRONIZATION; FILTER;
D O I
10.1109/TPEL.2011.2172000
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a frequency adaptive phase-locked loop (PLL) for use in single-phase systems. The main objective is to obtain a reliable synchronization signal even in polluted grids, where the fundamental frequency is contaminated with harmonics, or present variations in phase, amplitude, and/or frequency. The proposed PLL is based on the concept of a variable sampling period technique, already implemented in a three-phase digital synchronization method proposed by the authors. This single-phase method allows us to automatically adjust the sampling frequency to be an integer multiple of the line frequency. In this case, the phase error is calculated just by one multiplication, thereby reducing implementation. A sliding Goertzel transform-based filter is also used in the loop to reject the undesired effects of this phase error detector and line disturbances, such as harmonics. To stabilize the loop, a controller that maximizes the bandwidth with an acceptable transient is introduced. The characteristics of the proposed single-phase PLL are described and the experimental results obtained from a DSP implementation are presented. A set of comparative simulations between the proposed PLL and some single-phase PLL described in the literature are conducted to validate the method. The advantages of the proposed system over other methods analyzed are also dealt with. The robustness of the system is verified by the experimental tests conducted as well as by the harmonic filtering properties. The system is also characterized by its simple architecture, which allows us to provide a high dynamic response with a very much reduced number of calculations.
引用
收藏
页码:2396 / 2404
页数:9
相关论文
共 26 条
[1]   A self-synchronizing instrument for harmonic source detection in power systems [J].
Aiello, M ;
Cataliotti, A ;
Cosentino, V ;
Nuccio, S .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) :15-23
[2]  
[Anonymous], WISP 2007
[3]  
[Anonymous], IQM LIB VIRT FLOAT P
[4]  
[Anonymous], 2003, IEEE STANDARD 154720
[5]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[6]  
Bollen M.H., 2006, SIGNAL PROCESSING PO, V30
[7]   Variable Sampling Period Filter PLL for Distorted Three-Phase Systems [J].
Carugati, Ignacio ;
Maestri, Sebastian ;
Donato, Patricio G. ;
Carrica, Daniel ;
Benedetti, Mario .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (01) :321-330
[8]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[9]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[10]   A Novel Frequency-Adaptive PLL for Single-Phase Grid-Connected Converters [J].
Fang Xiong ;
Wang Yue ;
Li Ming ;
Liu Jinjun .
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, :414-419