Polishable and renewable DNA hybridization biosensors

被引:91
作者
Wang, J [1 ]
Fernandes, JR
Kubota, LT
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] UNESP, FC, Dept Quim, BR-17033360 Bauru, SP, Brazil
[3] UNICAMP, IQ, Dept Quim Analit, BR-13083970 Campinas, SP, Brazil
关键词
D O I
10.1021/ac980092z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Routine applications of DNA hybridization biosensors are often restricted by the need for regenerating the single-stranded (ss) probe for subsequent reuse. This note reports on a viable alternative to prolonged thermal or chemical regeneration schemes through the mechanical polishing of oligonucleotide-bulk-modified carbon composite electrodes. The surface of these biocomposite hybridization biosensors can be renewed rapidly and reproducibly by a simple extrusion/polishing protocol. The immobilized probe retains its hybridization activity on confinement in the interior of the carbon paste matrix, with the use of fresh surfaces erasing memory effects and restoring the original target response, to allow numerous hybridization/measurement cycles. We expect that such reusable nucleic acid modified composite electrodes can be designed for a wide variety of biosensing applications.
引用
收藏
页码:3699 / 3702
页数:4
相关论文
共 8 条
  • [1] PREPARATION AND CHARACTERIZATION OF TI(IV) OXIDE GRAFTED ONTO SILICA ON A SILICA-GEL SURFACE
    KUBOTA, LT
    GUSHIKEM, Y
    DECASTRO, S
    MOREIRA, JC
    [J]. COLLOIDS AND SURFACES, 1991, 57 (1-2): : 11 - 15
  • [2] Mikkelsen Susan R., 1996, Electroanalysis, V8, P15, DOI 10.1002/elan.1140080104
  • [3] VOLTAMMETRIC DNA BIOSENSOR FOR CYSTIC-FIBROSIS BASED ON A MODIFIED CARBON-PASTE ELECTRODE
    MILLAN, KM
    SARAULLO, A
    MIKKELSEN, SR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (18) : 2943 - 2948
  • [4] Amperometric immunosensors based on rigid conducting immunocomposites
    Santandreu, M
    Cespedes, F
    Alegret, S
    MartinezFabregas, E
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2080 - 2085
  • [5] EXTRACTIVE PRECONCENTRATION OF ORGANIC-COMPOUNDS AT CARBON PASTE ELECTRODES
    WANG, J
    FREIHA, BA
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 849 - 852
  • [6] POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES
    WANG, J
    VARUGHESE, K
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 318 - 320
  • [7] Peptide nucleic acid probes for sequence-specific DNA biosensors
    Wang, J
    Palecek, E
    Nielsen, PE
    Rivas, G
    Cai, XH
    Shiraishi, H
    Dontha, N
    Luo, DB
    Farias, PAM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (33) : 7667 - 7670
  • [8] Electrochemical biosensor for detecting DNA sequences from the pathogenic protozoan Cryptosporidium parvum
    Wang, J
    Rivas, G
    Parrado, C
    Cai, XH
    Flair, MN
    [J]. TALANTA, 1997, 44 (11) : 2003 - 2010