Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) -: Update 2008

被引:865
作者
Claudon, M. [1 ]
Cosgrove, D. [2 ]
Albrecht, T. [3 ,4 ,5 ]
Bolondi, L. [6 ]
Bosio, M. [7 ,8 ]
Calliada, F. [9 ]
Correas, J. -M. [10 ]
Darge, K. [11 ]
Dietrich, C. [12 ]
D'Onofrio, M. [13 ]
Evans, D. H. [14 ]
Filice, C. [15 ]
Greiner, L. [16 ]
Jaeger, K. [17 ]
de Jong, N. [18 ]
Leen, E. [19 ]
Lencioni, R. [20 ]
Lindsell, D. [21 ]
Martegani, A. [22 ]
Meairs, S. [23 ]
Nolsoe, C. [24 ]
Piscaglia, F. [25 ]
Ricci, P. [26 ]
Seidel, G. [27 ]
Skjoldbye, B. [28 ]
Solbiati, L. [29 ]
Thorelius, L. [30 ]
Tranquart, F. [31 ]
Weskott, H. P. [32 ]
Whittingham, T. [33 ]
机构
[1] Dept Radiol, Nancy, France
[2] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Imaging Sci Dept, Ctr Clin Sci, London, England
[3] Charite, Klin Radiol & Nukl Med, D-13353 Berlin, Germany
[4] Freie Univ, Berlin, Germany
[5] Humboldt Univ, Berlin, Germany
[6] St Orsola Marcello Malpighi Hosp, Div Internal Med, Bologna, Italy
[7] Magenta Hosp, Dept Paediat, Magenta, Italy
[8] Ultrasonog SIUMB, Adv Sch Paediat, Magenta, Italy
[9] Ist Radiol, Pavia, Italy
[10] Hop Necker Enfants Malad, Serv Radiol, Paris, France
[11] Univ Hosp, Dept Pediat Radiol, Wurzburg, Germany
[12] Caritas Krankenhaus, Bad Mergentheim, Germany
[13] Univ Verona, Ist Radiol, I-37100 Verona, Italy
[14] Dept Med Phys, Leicester, Leics, England
[15] Univ Pavia, IRCCS, S Matteo Hosp, Sch Med, I-27100 Pavia, Italy
[16] Helios Klinikum Wuppertal, Wuppertal, Germany
[17] Universitatsspital, Basel, Switzerland
[18] Acad Ziekenhuis, Rotterdam, Netherlands
[19] Univ London Imperial Coll Sci Technol & Med, Ctr Clin Sci, London SW7 2AZ, England
[20] Univ Pisa, Div Diagnost & Intervent Radiol, Dept Oncol Transplants & Adv Tecnol Med, I-56100 Pisa, Italy
[21] John Radcliffe Hosp Oxford, Dept Radiol, Oxford, England
[22] Serv Radiol, Como, Italy
[23] Univ Klinikum Mannheim, Neurol Klin, Mannheim, Germany
[24] Univ Copenhagen, Koge Hosp, Dept Radiol, DK-1168 Copenhagen, Denmark
[25] Dirigente Med 1 Livello, Dottore Recerca Ultrasonol Med, Spec Med Interna, Bologna, Italy
[26] Azienda Policlin Umberto 1, Dipartimento Sci Radiol, Rome, Italy
[27] Univ Schleswig Holstein, Dept Neurol, Lubeck, Germany
[28] Univ Copenhagen, Herlev Hosp, DK-1168 Copenhagen, Denmark
[29] Gen Hosp Busto Arsizio, Dept Radiol, Busto Arsizio, Italy
[30] Herlev Hosp, Radiol Afdeling, Herlev, Denmark
[31] Unite Fonct Ultrasons Directeur CIT, Tours, France
[32] Krankenhaus Siloah, Med Klin 2, Hannover, Germany
[33] Newcastle Gen Hosp, Dept Reg Med Phys, Newcastle Upon Tyne, Tyne & Wear, England
来源
ULTRASCHALL IN DER MEDIZIN | 2008年 / 29卷 / 01期
关键词
contrast agent; liver urinary; v. ureteric reflux; pancreas; trauma; transcranial US;
D O I
10.1055/s-2007-963785
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
[No abstract available]
引用
收藏
页码:28 / 44
页数:17
相关论文
共 143 条
[1]   Stimulated acoustic emission with the ultrasound contrast agent levovist: a clinically useful contrast effect with liver-specific properties [J].
Albrecht, T ;
Blomley, MJK ;
Heckemann, RA ;
Cosgrove, DO ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Hoffmann, CW ;
Bauer, A .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01) :61-67
[2]   Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: Multicenter study [J].
Albrecht, T ;
Blomley, MJK ;
Burns, PN ;
Wilson, S ;
Harvey, CJ ;
Leen, E ;
Claudon, M ;
Calliada, F ;
Correas, JM ;
LaFortune, M ;
Campani, R ;
Hoffmann, CW ;
Cosgrove, DO ;
LeFevre, F .
RADIOLOGY, 2003, 227 (02) :361-370
[3]   Harmonic US imaging of vesicoureteric reflux in children: usefulness of a second generation US contrast agent [J].
Ascenti, G ;
Zimbaro, G ;
Mazziotti, S ;
Chimenz, R ;
Fede, C ;
Visalli, C ;
Scribano, E .
PEDIATRIC RADIOLOGY, 2004, 34 (06) :481-487
[4]   Usefulness of power Doppler and contrast-enhanced sonography in the differentiation of hyperechoic renal masses [J].
Ascenti, G ;
Zimbaro, G ;
Mazziotti, S ;
Gaeta, M ;
Settineri, N ;
Scribano, E .
ABDOMINAL IMAGING, 2001, 26 (06) :654-660
[5]  
Averkiou Michalakis, 2003, Ultrasound Q, V19, P27, DOI 10.1097/00013644-200303000-00004
[6]  
Barnett SB, 2007, ULTRASOUND MED BIOL, V33, P173, DOI 10.1016/j.ultrasmedbio.2006.07.002
[7]   Which continuous US scanning mode is optimal for the detection of vascularity in liver lesions when enhanced with a second generation contrast agent? [J].
Basilico, R ;
Blomley, MJK ;
Harvey, CJ ;
Filippone, A ;
Heckemann, RA ;
Eckersley, RJ ;
Cosgrove, DO .
EUROPEAN JOURNAL OF RADIOLOGY, 2002, 41 (03) :184-191
[8]  
Bauer A, 2003, CONTRAST-ENHANCED ULTRASOUND OF LIVER DISEASES, P21
[9]   Comparison of contrast harmonic imaging in B-Mode with stimulated acoustic emission, conventional B-Mode US and spiral CT in the detection of liver lesions [J].
Beissert, M ;
Jenett, M ;
Keberle, M ;
Kessler, C ;
Klein, D ;
Beer, M ;
Hahn, D .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (04) :361-366
[10]   Detection of liver metastases -: Comparison of contrast -: Enhanced ultrasound using first versus second generation contrast agents [J].
Bernatik, T ;
Becker, D ;
Neureiter, D ;
Hänsler, J ;
Frieser, M ;
Schaber, S ;
Hahn, EG ;
Strobel, D .
ULTRASCHALL IN DER MEDIZIN, 2003, 24 (03) :175-179