Blood protein interactions with titanium surfaces

被引:39
作者
Walivaara, B
Askendal, A
Lundstrom, I
Tengvall, P
机构
[1] Linköping University, Department of Physics and Measurement Technology, Laboratory of Applied Physics, Linköpin
关键词
ellipsometry; complement activation; antibodies; titanium; coagulation;
D O I
10.1163/156856297X00560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Protein adsorption and complement activation were studied on thin evaporated films of titanium (Ti). The surfaces were cleaned in either a radio frequency (RF) plasma unit, or washed sequentially in trichloroethylene, acetone, ethanol, and water. Both methods resulted in hydrophilic surfaces with low carbon contamination on the outermost oxide (approximate to 11-13 at%) In situ ellipsometry suggested that Ti is an intrinsic coagulation activator in vitro, since significant amounts of factor XII (F XII) and high molecular weight kininogen (HMWK) were found on the surfaces after 1 min incubation in heparin plasma. Ellipsometry, performed after serum incubations ranging from 15 s to 30 min showed that the total amount of serum proteins and the deposition of antibodies to complement factor 3c (C3c) increased with serum incubation time. ELISA methods showed increased levels of free iC3b in serum after 10 min incubation of the surfaces, but no detectable amounts of C3 convertase fractions C4d or Bb. Ellipsometric results indicated, however, an increased deposition of antibodies to C1q and IgG on Ti after short serum incubation times. The combined results indicate that Ti-surfaces initially activate complement through the classical pathway. The activation then continues via a positive amplification loop where increased amounts of C3 are deposited on the surfaces via the alternative pathway.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 12 条
[1]   THE INTERFACE ZONE OF INORGANIC IMPLANTS INVIVO - TITANIUM IMPLANTS IN BONE [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
KASEMO, B ;
LARSSON, K ;
LUNDSTROM, I ;
MCQUEEN, DH ;
SKALAK, R .
ANNALS OF BIOMEDICAL ENGINEERING, 1983, 11 (01) :1-27
[2]   ELLIPSOMETRY AS A TOOL TO STUDY ADSORPTION BEHAVIOR OF SYNTHETIC AND BIOPOLYMERS AT AIR-WATER-INTERFACE [J].
DEFEIJTER, JA ;
BENJAMINS, J ;
VEER, FA .
BIOPOLYMERS, 1978, 17 (07) :1759-1772
[3]  
GENGVALL P, 1996, IN PRESS J BIOMED MA
[4]   BONE RESPONSE TO SURFACE-MODIFIED TITANIUM IMPLANTS - STUDIES ON ELECTROPOLISHED IMPLANTS WITH DIFFERENT OXIDE THICKNESSES AND MORPHOLOGY [J].
LARSSON, C ;
THOMSEN, P ;
LAUSMAA, J ;
RODAHL, M ;
KASEMO, B ;
ERICSON, LE .
BIOMATERIALS, 1994, 15 (13) :1062-1074
[5]  
MACCRACKIN FL, 1969, 479 NBS
[6]  
MARTENSSON J, 1993, J COLLOID INTERF SCI, V155, P43
[8]   Complement activation by 3-mercapto-1,2-propanediol immobilized on gold surfaces [J].
Tengvall, P ;
Askendal, A ;
Lundstrom, I .
BIOMATERIALS, 1996, 17 (10) :1001-1007
[9]   Blood protein interactions with chromium surfaces [J].
Walivaara, B ;
Askendal, A ;
Krozer, A ;
Lundstrom, I ;
Tengvall, P .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1996, 8 (01) :49-62
[10]   TITANIUM WITH DIFFERENT OXIDES - IN-VITRO STUDIES OF PROTEIN ADSORPTION AND CONTACT ACTIVATION [J].
WALIVAARA, B ;
ARONSSON, BO ;
RODAHL, M ;
LAUSMAA, J ;
TENGVALL, P .
BIOMATERIALS, 1994, 15 (10) :827-834