Detection of bovine whey proteins by on-column derivatization capillary electrophoresis with laser-induced fluorescence monitoring

被引:36
作者
Benito, I
Marina, ML
Saz, JM
Diez-Masa, JC
机构
[1] CSIC, Inst Quim Organ Gen, E-28006 Madrid, Spain
[2] Univ Alcala de Henares, Fac Ciencias, Dept Quim Analit, Alcala De Henares 28871, Spain
关键词
whey; derivatization; electrophoresis; proteins;
D O I
10.1016/S0021-9673(99)00272-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
1-Anilinonaphthalene-8-sulfonic acid (1,8-ANS), 4,4'-dianilino-1,1'-binaphthyl-5,5'-disulfonic acid (bis-ANS) and 2-(p-toluidino)naphthalene-6-sulfonic acid (2,6-TNS) were evaluated as additives in different buffers for the detection of bovine whey proteins using laser-induced fluorescence (LIF) monitoring in capillary electrophoresis (CE). These N-arylaminonaphthalene sulfonates furnish a large fluorescence emission when associated to some proteins whereas their emission in aqueous buffers, such as those used in CE separations, is very small. To select the best detection conditions, the fluorescence of these probes was first compared using experiments carried out in a fluorescence spectrophotometer. Using bovine serum albumin (BSA) as a model protein, it was demonstrated that 2-(N-cyclohexylamino)ethanesulfonic acid (CHES) buffer (pH 8 and pH 10.2) and the fluorescent probe 2,6-TNS gave rise to the highest increase in fluorescence for BSA. When the composition of these separation buffers was optimized for the electrophoretic separations, CHES buffer, pH 10.2 was chosen as the most suitable buffer to detect bovine whey proteins. The limit of detection obtained for some whey proteins in CE separations was about 6.10(-8) M for BSA, 3.10(-7) M for beta-lactoglobulin A (beta-LGA), 3.10(-7) M for beta-lactoglobulin B (beta-LGB), and 3.10(-6) M for alpha-lactalbumin (alpha-LA). These detection limits were compared to those achieved using UV detection under the same separation conditions. The results showed that the detection limits of BSA, beta-LGA and beta-LGB were twice as good using LIF than with UV detection. However, the limit of detection for alpha-LA was better when UV was used. The applicability of LIF detection to CE separation of whey proteins in bovine milk samples was also demonstrated. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 42 条
[1]  
CHEN RF, 1967, FLUORESCENCE THEORY
[2]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[3]   Cloned transgenic calves produced from nonquiescent fetal fibroblasts [J].
Cibelli, JB ;
Stice, SL ;
Golueke, PJ ;
Kane, JJ ;
Jerry, J ;
Blackwell, C ;
de Leon, FAP ;
Robl, JM .
SCIENCE, 1998, 280 (5367) :1256-1258
[4]   Polyacrylamide-coated capillaries probed by atomic force microscopy:: Correlation between surface topography and electrophoretic performance [J].
Cifuentes, A ;
Díez-Masa, JC ;
Fritz, J ;
Anselmetti, D ;
Bruno, AE .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3458-3462
[5]   SELECTIVE PRECONCENTRATION FOR CAPILLARY ZONE ELECTROPHORESIS USING PROTEIN-G IMMUNOAFFINITY CAPILLARY CHROMATOGRAPHY [J].
COLE, LJ ;
KENNEDY, RT .
ELECTROPHORESIS, 1995, 16 (04) :549-556
[6]   Microchip-based capillary electrophoresis of human serum proteins [J].
Colyer, CL ;
Mangru, SD ;
Harrison, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :271-276
[7]   COOPERATIVE EFFECTS IN BINDING BY BOVINE SERUM ALBUMIN .I. BINDING OF 1-ANILINO-8-NAPHTHALENESULFONATE . FLUORIMETRIC TITRATIONS [J].
DANIEL, E ;
WEBER, G .
BIOCHEMISTRY, 1966, 5 (06) :1893-&
[8]   Multiple peaks in high-performance liquid chromatography of proteins - beta-Lactoglobulins eluted in a hydrophobic interaction chromatography system [J].
deFrutos, M ;
Cifuentes, A ;
DiezMasa, JC .
JOURNAL OF CHROMATOGRAPHY A, 1997, 778 (1-2) :43-52
[9]   DETERMINATION OF MILK-PROTEINS BY CAPILLARY ELECTROPHORESIS [J].
DEJONG, N ;
VISSER, S ;
OLIEMAN, C .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :207-213
[10]   EFFECTS OF VARIOUS HEAT-TREATMENTS ON STRUCTURE AND SOLUBILITY OF WHEY PROTEINS [J].
DEWIT, JN ;
KLARENBEEK, G .
JOURNAL OF DAIRY SCIENCE, 1984, 67 (11) :2701-2710