The effect of the mobile phase additives on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography-electrospray mass spectrometry

被引:163
作者
García, MC [1 ]
机构
[1] Univ Alcala De Henares, Fac Quim, Dept Quim Analit, E-28871 Alcala De Henares, Spain
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 825卷 / 02期
关键词
reversed-phase chromatography; size-exclusion chromatography; ion-exchange chromatography; affinity chromatography; protein; peptide; electrospray mass spectrometry;
D O I
10.1016/j.jchromb.2005.03.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The study of the effect of mobile phases on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography (HPLC)-electrospray mass spectrometry (ESI-MS) has been the aim of this review. Reversed-phase chromatography (RPLC) is the chromatographic mode most suitable for coupling with ESI-MS since mobile phases containing organic modifiers are used. The analysis of proteins and peptides by RPLC mostly involves the use of trifluoroacetic acid (TFA) as an ion-pairing agent despite its being a strong suppressor of the MS signal. Different studies reporting the effects of using other ion-pairing agents (other perfluorinated acids, acetic acid, formic acid, etc.) and buffers (ammonium acetate, ammonium formate, ammonium bicarbonate, morpholine, etc.) in RPLC-ESI-MS of proteins and peptides did not yield a single strong candidate that could generally replace TFA. The enhancement in sensitivity with other reagents observed in some cases strongly depended on the analyte, the experimental conditions used, and the mass spectrometer and, usually, it did not compensate for the loss in separation resolution related to TFA. The examples of direct coupling of affinity, size-exclusion, or ion-exchange chromatography (IEC) to ESI-MS are very limited because of incompatibilities related to the use of mobile phases containing high salt concentrations. To overcome this problem, an intermediate desalting step is needed. Multidimensional chromatography, microdialysis, and ion-capture modules can be used to couple these chromatographic modes with ESI-MS. Multidimensional chromatography with RPLC as a second dimension has most often been used. Although most examples involve the trap and analysis in the second dimension of a certain part of the first separation, some comprehensive analyses of the entire sample in the second dimension have also appeared. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 123
页数:13
相关论文
共 102 条
[61]  
MILLER C, 2000, IMPACT ION PAIR REAG
[62]   Preliminary studies on selenium-containing proteins in Brassica juncea by size exclusion chromatography and fast protein liquid chromatography coupled to ICP-MS [J].
Mounicou, S ;
Meija, J ;
Caruso, J .
ANALYST, 2004, 129 (02) :116-123
[63]   SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. OPTIMIZING SAMPLE PRETREATMENT AND MOBILE PHASE CONDITIONS [J].
NUGENT, KD ;
BURTON, WG ;
SLATTERY, TK ;
JOHNSON, BF ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :381-397
[64]   ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF PHOSPHOPEPTIDES ISOLATED BY ONLINE IMMOBILIZED METAL-ION AFFINITY-CHROMATOGRAPHY [J].
NUWAYSIR, LM ;
STULTS, JT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (08) :662-669
[65]   PROCESSING OF PRODYNORPHIN-DERIVED PEPTIDES IN STRIATAL EXTRACTS - IDENTIFICATION BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY LINKED TO SIZE-EXCLUSION CHROMATOGRAPHY [J].
NYLANDER, I ;
TANNO, K ;
WINTER, A ;
SILBERRING, J .
LIFE SCIENCES, 1995, 57 (02) :123-129
[66]   Automated affinity chromatography measurements of compound mixtures using a lab-on-valve apparatus coupled to electrospray ionization mass spectrometry [J].
Ogata, Y ;
Scampavia, L ;
Carter, TL ;
Fan, E ;
Turecek, F .
ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) :161-168
[67]   Automated affinity capture-release of biotin-containing conjugates using a lab-on-valve apparatus coupled to UV/visible and electrospray ionization mass Spectrometry [J].
Ogata, Y ;
Scampavia, L ;
Ruzicka, J ;
Scott, CR ;
Gelb, MH ;
Turecek, F .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4702-4708
[68]   Comprehensive on-line LC/LC/MS of proteins [J].
Opiteck, GJ ;
Lewis, KC ;
Jorgenson, JW ;
Anderegg, RJ .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1518-1524
[69]   Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides [J].
Opiteck, GJ ;
Jorgenson, JW ;
Anderegg, RJ .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2283-2291
[70]   Comprehensive two-dimensional high-performance liquid chromatography for the isolation of overexpressed proteins and proteome mapping [J].
Opiteck, GJ ;
Ramirez, SM ;
Jorgenson, JW ;
Moseley, MA .
ANALYTICAL BIOCHEMISTRY, 1998, 258 (02) :349-361