Label-Free Porous Silicon Immunosensor for Broad Detection of Opiates in a Blind Clinical Study and Results Comparison to Commercial Analytical Chemistry Techniques

被引:38
作者
Bonanno, Lisa M. [1 ]
Kwong, Tai C. [2 ]
DeLouise, Lisa A. [1 ,3 ]
机构
[1] Univ Rochester, Dept Biomed Engn, Rochester, NY USA
[2] Univ Rochester, Med Ctr, Dept Pathol & Lab Med, Rochester, NY 14642 USA
[3] Univ Rochester, Med Ctr, Dept Dermatol, Rochester, NY 14642 USA
关键词
MASS-SPECTROMETRY; PHOTONIC CRYSTALS; PROTEASE ACTIVITY; URINE; BIOSENSOR; IMMUNOASSAY; SENSITIVITY; OXYCODONE; SENSOR;
D O I
10.1021/ac101804s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we evaluate for the first time the performance of a label free porous silicon (PSI) immunosensor assay in a blind clinical study designed to screen authentic patient urine specimens for a broad range of opiates The PSI opiate immunosensor achieved 96% concordance with liquid chromatography-mass spectrometry/tandem mass spectrometry (LC-MS/MS) results on samples that underwent standard opiate testing (n = 50) In addition, successful detection of a commonly abused opiate, oxycodone, resulted in 100% qualitative agreement between the PSi opiate sensor and LC-MS/MS In contrast, a commercial broad opiate immunoassay technique (CEDIA) achieved 65% qualitative concordance with LCMS/MS Evaluation of important performance attributes including precision, accuracy, and recovery was completed on blank urine specimens spiked with test analytes Variability of morphine detection as a model opiate target was <9% both within run and between day at and above the cutoff limit of 300 ng mL(-1) This study validates the analytical screening capability of label-free PSI opiate immunosensors in authentic patient samples and is the first semiquantitative demonstration of the technology's successful clinical use These results motivate future development of label-free PSI technology to reduce complexity and cost of diagnostic testing particularly in a point-of care setting
引用
收藏
页码:9711 / 9718
页数:8
相关论文
共 46 条
[1]   Can an immunoassay become a standard technique in detecting oxycodone and its metabolites? [J].
Abadie, JM ;
Allison, KH ;
Black, DA ;
Garbin, J ;
Saxon, AJ ;
Bankson, DD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (08) :825-829
[2]   Evaluation of the DRI® oxycodone immunoassay for the detection of oxycodone in urine [J].
Backer, RC ;
Monforte, JR ;
Poklis, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (07) :675-677
[3]   Whole blood optical biosensor [J].
Bonanno, Lisa M. ;
DeLouise, Lisa A. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (03) :444-448
[4]   Integration of a Chemical-Responsive Hydrogel into a Porous Silicon Photonic Sensor for Visual Colorimetric Readout [J].
Bonanno, Lisa M. ;
DeLouise, Lisa A. .
ADVANCED FUNCTIONAL MATERIALS, 2010, 20 (04) :573-578
[5]   Tunable Detection Sensitivity of Opiates in Urine via a Label-Free Porous Silicon Competitive Inhibition Immunosensor [J].
Bonanno, Lisa M. ;
DeLouise, Lisa A. .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :714-722
[6]  
BOWN AMT, 2000, PHYS STATUS SOLIDI A, V182, P547
[7]  
Boyd J.C., 2008, TIETZ FUNDAMENTALS C, V6th, P201
[8]  
Broussard LA, 1997, CLIN CHEM, V43, P1029
[9]   Use of the terms "recovery" and "apparent recovery" in analytical procedures - (IUPAC recommendations 2002) [J].
Burns, DT ;
Danzer, K ;
Townshend, A .
PURE AND APPLIED CHEMISTRY, 2002, 74 (11) :2201-2205
[10]   Biomolecular screening with encoded porous-silicon photonic crystals [J].
Cunin, F ;
Schmedake, TA ;
Link, JR ;
Li, YY ;
Koh, J ;
Bhatia, SN ;
Sailor, MJ .
NATURE MATERIALS, 2002, 1 (01) :39-41