Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model

被引:141
作者
Collins, CM
Smith, MB
机构
[1] Penn State Univ, Coll Med, Dept Radiol H066, Ctr NMR Res, Hershey, PA 17033 USA
[2] Penn State Univ, Coll Med, Dept Physiol, Hershey, PA 17033 USA
[3] Univ Penn, Dept Bioengn, Philadelphia, PA USA
关键词
calculations; SNR; power; MRI; high field;
D O I
10.1002/mrm.1092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Calculations of the radiofrequency magnetic (B-1) field, SAR, and SNR as functions of frequency between 64 and 345 MHz for a surface coil against an anatomically-accurate human chest are presented. Calculated B-1 field distributions are in good agreement with previously-published experimental results up to 175 MHz, especially considering the dependence of field behavior on subject anatomy. Calculated SNR in the heart agrees well with theory for low frequencies (nearly linear increase with B-0 field strength). Above 175 MHz, the trend in SNR with frequency begins to depend largely on location in the heart. At all frequencies, present limits on local (1 g) SAR levels are exceeded before limits on whole-body average limits. At frequencies above 175 MHz, limits on SAR begin to be an issue in some common imaging sequences. These results are relevant for coils and subjects similar to those modeled here. Magn Reson Med 45:692-699, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:692 / 699
页数:8
相关论文
共 27 条
[11]  
Gabriel C., 1996, Environmental Health
[12]   THE FIELD-DEPENDENCE OF NMR IMAGING .2. ARGUMENTS CONCERNING AN OPTIMAL FIELD-STRENGTH [J].
HOULT, DI ;
CHEN, CN ;
SANK, VJ .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :730-746
[13]   SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES [J].
HOULT, DI ;
LAUTERBUR, PC .
JOURNAL OF MAGNETIC RESONANCE, 1979, 34 (02) :425-433
[14]  
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO
[15]  
2-D
[16]  
Hoult DI, 2000, CONCEPT MAGNETIC RES, V12, P173, DOI 10.1002/1099-0534(2000)12:4<173::AID-CMR1>3.0.CO
[17]  
2-Q
[18]  
HUANG H K, 1976, Computers in Biology and Medicine, V6, P337, DOI 10.1016/0010-4825(76)90070-6
[19]  
*INT EL COMM, 1995, 601233 IEC
[20]   Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications [J].
Jin, JM ;
Chen, J ;
Chew, WC ;
Gan, H ;
Magin, RL ;
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2719-2738