Fat-suppressed steady-state free precession imaging using phase detection

被引:96
作者
Hargreaves, BA
Vasanawala, SS
Nayak, KS
Hu, BS
Nishimura, DG
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Palo Alto Med Fdn, Palo Alto, CA USA
关键词
steady-state; SSFP; TrueFISP; fat suppression; angiography;
D O I
10.1002/mrm.10488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetition time (TR). Appropriate selection of the TR results in a 180degrees phase difference between lipid and water signals. This phase difference can be used for fat-water separation in SSFP without any increase in scan time. The technique is shown to produce excellent non-contrast-enhanced, flow-independent angiograms of the peripheral vasculature. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:210 / 213
页数:4
相关论文
共 24 条
[1]  
BLOCK WF, 2000, P 8 ISMRM SCI M DENV, P161
[2]   SIGNAL INTENSITY IN FAST NMR IMAGING WITH SHORT REPETITION TIMES [J].
BUXTON, RB ;
FISEL, CR ;
CHIEN, D ;
BRADY, TJ .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (03) :576-585
[3]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[4]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[5]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[6]   SPIN ECHOES [J].
HAHN, EL .
PHYSICAL REVIEW, 1950, 80 (04) :580-594
[7]  
HARDY CJ, 2002, P 10 ANN M ISMRM HON, P473
[8]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158
[9]  
HEID O, 1995, P 3 ANN M ISMRM NIC, P481
[10]   Multishot EPI-SSFP in the heart [J].
Herzka, DA ;
Kellman, P ;
Aletras, AH ;
Guttman, MA ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :655-664