A structural model of the forced compression of the fingertip pulp

被引:91
作者
Serina, ER
Mockensturm, E
Mote, CD
Rempel, D
机构
[1] Univ Calif Berkeley, Dept Med, Ergon Program, Richmond, CA 94804 USA
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
关键词
fingertip; pulp; compression; model; finite deformation theory;
D O I
10.1016/S0021-9290(98)00067-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The fingertip pulp modulates the force transmitted to the underlying musculoskeletal system during finger contact on external bodies. A model of the fingertip pulp is needed to represent the transmission of forces to the tendons, muscles, and bone during these contacts. In this study, a structural model of the in vivo human fingertip was developed that incorporates both the material inhomogeneity and geometry. Study objectives were to determine (1) if this fingertip model can predict the force-displacement and force-contact area responses of the in vivo human fingertip during contact with a flat, rigid surface, and (2) if the stresses and strains predicted by this model are consistent with the tactile sensing functionality of the in vivo human fingertip. The in vivo fingertip pulp was modeled as an inflated, ellipsoidal membrane, containing an incompressible fluid, that is quasi-statically compressed against a flat, Frictionless surface. The membrane was assigned properties of skin (Veronda and Westmann, 1970) and when inflated, possessed dimensions approximating those of a human fingertip. Finite deformation was allowed. The model was validated by the gulp force-displacement relationship obtained by Serina et al. (1997) and by measurements of the contact area when the fingertip was pressed against a rigid surface with contact forces between 0.25 and 7.0N. Model predictions represent the experimental data sufficiently well, suggesting that geometry, inhomogeneous material structure, and initial skin tension appear to represent the nonlinear response of the in vivo human fingertip pulp under compression. The predicted response of the fingertip pulp is consistent with its functionality as a tactile sensor. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:639 / 646
页数:8
相关论文
共 31 条
[11]  
Finlay J. B, 1973, PERSPECTIVES BIOMEDI, P165
[12]  
Gibson T., 1970, DERMIS, P19
[13]  
GLICENSTEIN J, 1981, HAND, V1
[14]  
Green AE., 1960, LARGE ELASTIC DEFORM
[15]   SENSITIVITY TO EDGES OF MECHANORECEPTIVE AFFERENT UNITS INNERVATING THE GLABROUS SKIN OF THE HUMAN HAND [J].
JOHANSSON, RS ;
LANDSTROM, U ;
LUNDSTROM, R .
BRAIN RESEARCH, 1982, 244 (01) :27-32
[16]   THE MEASUREMENT AND MODELING OF THE MECHANICAL-PROPERTIES OF HUMAN-SKIN INVIVO .1. THE MEASUREMENT [J].
MANSCHOT, JFM ;
BRAKKEE, AJM .
JOURNAL OF BIOMECHANICS, 1986, 19 (07) :511-515
[17]   VOLUME COMPRESSIBILITY OF HUMAN ABDOMINAL SKIN [J].
NORTH, JF ;
GIBSON, F .
JOURNAL OF BIOMECHANICS, 1978, 11 (04) :203-&
[18]   TACTILE SPATIAL-RESOLUTION .3. A CONTINUUM-MECHANICS MODEL OF SKIN PREDICTING MECHANORECEPTOR RESPONSES TO BARS, EDGES, AND GRATINGS [J].
PHILLIPS, JR ;
JOHNSON, KO .
JOURNAL OF NEUROPHYSIOLOGY, 1981, 46 (06) :1204-1225
[19]   TACTILE SPATIAL-RESOLUTION .2. NEURAL REPRESENTATION OF BARS, EDGES, AND GRATINGS IN MONKEY PRIMARY AFFERENTS [J].
PHILLIPS, JR ;
JOHNSON, KO .
JOURNAL OF NEUROPHYSIOLOGY, 1981, 46 (06) :1192-1203
[20]   Force response of the fingertip pulp to repeated compression - effects of loading rate, loading angle and anthropometry [J].
Serina, ER ;
Mote, CD ;
Rempel, D .
JOURNAL OF BIOMECHANICS, 1997, 30 (10) :1035-1040