EUS in patients with benign and malignant lymphadenopathy

被引:69
作者
Faigel, DO [1 ]
机构
[1] Oregon Hlth Sci Univ, Portland VA Med Ctr, Dept Med, Div Gastroenterol, Portland, OR 97201 USA
关键词
D O I
10.1067/mge.2001.114060
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The EUS appearance of lymph nodes in patients undergoing evaluation for malignancy was studied. Methods: In 378 patients EUS characteristics were assessed: size of tumor, largest lymph node size, number of lymph nodes, distance of lymph nodes from the tumor, and on a 5-point visual analogue scale(1 = least malignant to 5 = most malignant), roundness, homogeneity, and echogenicity, A morphology score (sum of roundness, homogeneity, and echogenicity) was calculated. Findings were compared with fine needle aspiration or surgical histopathology in 238 patients. Results: When using multivariate analysis, only lymph node size (1.4 +/- 0.1 cm vs. 1.7 +/- 0.1 cm, p = 0.001), distance from tumor (3.1 +/- 0.4 cm vs. 1.6 +/- 0.4 cm, p = 0.013), and morphology score (9.9 +/- 0.3 vs. 11.9 +/- 0.3, p = 0.001) for benign versus malignant lymph nodes (mean +/- SEM) were significant. Lymph node size was significant for esophageal cancer (p = 0.006) and other mediastinal lymph nodes (p = 0.007) but not for pancreaticobiliary malignancies (p = 0.1) or celiac lymph nodes (p = 0.4). Distance from the tumor was significant for pancreaticobiliary (p = 0.01) but not esophageal cancers (p = 0.7). Morphology was significant for all sites. The presence of at least one lymph node of 1 cm or greater within 1 cm of the tumor and with a morphology score of 14 or greater had a positive predictive value of 81% (prevalence = 13%). A morphology score of 6 or less had a negative predictive value of 92% (prevalence = 12%). Conclusions: Patients with malignant adenopathy have lymph nodes that are larger, closer to the primary tumor, rounder, darker, and more homogeneous than those of patients without malignant adenopathy.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 23 条
[21]   Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment [J].
Wiersema, MJ ;
Vilmann, P ;
Giovannini, M ;
Chang, KJ ;
Wiersema, LM .
GASTROENTEROLOGY, 1997, 112 (04) :1087-1095
[22]   MEDIASTINAL LYMPH-NODE DETECTION WITH ENDOSONOGRAPHY [J].
WIERSEMA, MJ ;
HASSIG, WM ;
HAWES, RH ;
WONN, MJ .
GASTROINTESTINAL ENDOSCOPY, 1993, 39 (06) :788-793
[23]   Endoscopic ultrasound guided fine needle aspiration biopsy: a large single centre experience [J].
Williams, DB ;
Sahai, AV ;
Aabakken, L ;
Penman, ID ;
van Velse, A ;
Webb, J ;
Wilson, M ;
Hoffman, BJ ;
Hawes, RH .
GUT, 1999, 44 (05) :720-726