A Field Survey of Occupancy and Air-Conditioner Use Patterns in Open Plan Offices

被引:19
作者
Yun, Geun Young [1 ]
Kong, Hyo Joo [1 ]
Kim, Jeong Tai [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, South Korea
关键词
Occupant behaviour; nergy use; Occupancy patterns; Air-conditioner use; Energy simulation; Building environment conditions; VENTILATED OFFICES; THERMAL COMFORT; BUILDINGS; MODEL;
D O I
10.1177/1420326X10388883
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the survey results from a field monitoring study of office occupancy and air-conditioner use pattern of an office building in Seoul, Korea, from 20 July to 29 September 2009. The survey has an aim to reveal the relationship between the indoor environment conditions and occupancy; and the use patterns of air-conditioners and energy consumption in offices. The results showed that the average occupied time of the investigated offices was 15.48 h per day for normal weekdays, which was longer than expected occupancy schedules assumed for offices for the design prediction of building energy consumption. This study also presents the hourly profiles of air-conditioner use and evaluates the effect of longer occupancy period on energy consumption for air cooling in open-plan offices in Korea. The findings of this study could contribute to inform building energy simulation based on realistic office occupancy profile provided by the survey, which would therefore inform better operation of air-conditioners and more efficient use of energy in building management.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 15 条
[1]  
Baker Nick., 2000, ENERGY ENV ARCHITECT
[2]   Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices [J].
Daghigh, R. ;
Adam, N. M. ;
Sahari, B. B. .
INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) :113-122
[3]  
DoE, 2010, EnergyPlus Input output reference
[4]  
FRACASTARO GV, 1983, GUIDING PRINCIPLES C
[5]   Interactions with window openings by office occupants [J].
Haldi, Frederic ;
Robinson, Darren .
BUILDING AND ENVIRONMENT, 2009, 44 (12) :2378-2395
[6]   Using carbon dioxide concentration to assess indoor air quality in offices [J].
Hui, P. S. ;
Wong, L. T. ;
Mui, K. W. .
INDOOR AND BUILT ENVIRONMENT, 2008, 17 (03) :213-219
[7]   Patterns and Implications of User Control Actions in Buildings [J].
Mahdavi, Ardeshir .
INDOOR AND BUILT ENVIRONMENT, 2009, 18 (05) :440-446
[8]   On the Use of Windcatchers in Schools: Climate Change, Occupancy Patterns, and Adaptation Strategies [J].
Mavrogianni, A. ;
Mumovic, D. .
INDOOR AND BUILT ENVIRONMENT, 2010, 19 (03) :340-354
[9]   2-TO-ONE DISCREPANCY BETWEEN MEASURED AND PREDICTED PERFORMANCE OF A LOW-ENERGY OFFICE BUILDING - INSIGHTS FROM A RECONCILIATION BASED ON THE DOE-2 MODEL [J].
NORFORD, LK ;
SOCOLOW, RH ;
HSIEH, ES ;
SPADARO, GV .
ENERGY AND BUILDINGS, 1994, 21 (02) :121-131
[10]   A generalised stochastic model for the simulation of occupant presence [J].
Page, J. ;
Robinson, D. ;
Morel, N. ;
Scartezzini, J. -L. .
ENERGY AND BUILDINGS, 2008, 40 (02) :83-98