The effect of peripheral resistance on impedance cardiography measurements in the anesthetized dog

被引:19
作者
Critchley, LAH
Peng, ZY
Fok, BS
James, AE
机构
[1] Chinese Univ Hong Kong, Lab Anim Serv Ctr, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Anesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
关键词
D O I
10.1213/01.ANE.0000150602.40554.EB
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
In the vasodilated and septic patient, the impedance method of measuring cardiac output (CO) may underestimate the true value. In this study, we sought to determine whether impedance CO (COIC) measurements are influenced by total peripheral resistance (TPR). In eight anesthetized and ventilated dogs, a high-precision flowprobe was placed on the ascending aorta, and direct CO was measured (CO flowprobe (COFP)). Mean arterial blood pressure was measured from the femoral artery. Simultaneous COIC measurements were made. TPR (mean arterial blood pressure x 80/COFP) was varied over 1-2 h by using infusions of phenylephrine and adrenaline and inhaled halothane. The bias between methods of CO measurement (COIC - COFP) was calculated and compared with TPR by using correlation and regression analysis. A total of 547 pairs of CO measurements were collected from the 8 dogs as TPR was varied. COFP changed by a mean of 190% (range, 89%-425%), and TPR changed by a mean of 266% (range, 94%-580%) during the experiment. The impedance method underestimated CO when TPR was low and overestimated CO when TPR was high. There was a logarithmic relationship between the CO bias and TPR. Correlation coefficients (r) between the CO bias and TPR ranged from 0.46 to 0.89 (P < 0.0001). The bias changed by 0.62 +/- 1.8 L/min, or by 34%, every time TPR halved or doubled, This finding explains the poor agreement between COIC and other methods of CO measurement found in validation studies involving critically ill patients.
引用
收藏
页码:1708 / 1712
页数:5
相关论文
共 27 条
[1]
Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization [J].
Barin, E ;
Haryadi, DG ;
Schookin, SI ;
Westenskow, DR ;
Zubenko, VG ;
Beliaev, KR ;
Morozov, AA .
CRITICAL CARE MEDICINE, 2000, 28 (03) :698-702
[2]
CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[3]
A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[4]
Blomqvist C.G., 1983, HDB PHYSL, P1025, DOI [DOI 10.1002/CPHY.CP020328, 10.1002/cphy.cp020328]
[5]
THE ORIGIN OF THE VARIATIONS OF BODY IMPEDANCE OCCURRING DURING THE CARDIAC CYCLE [J].
BONJER, FH ;
VANDENBERG, J ;
DIRKEN, MNJ .
CIRCULATION, 1952, 6 (03) :415-420
[6]
THORACIC ELECTRICAL BIOIMPEDANCE MEASUREMENT OF CARDIAC-OUTPUT - NOT READY FOR PRIME-TIME [J].
CLARKE, DE ;
RAFFIN, TA .
CRITICAL CARE MEDICINE, 1993, 21 (08) :1111-1112
[7]
The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[8]
Impedance cardiography - The impact of new technology [J].
Critchley, LAH .
ANAESTHESIA, 1998, 53 (07) :677-684
[9]
Non-invasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man [J].
Critchley, LAH ;
Conway, F ;
Anderson, PJ ;
Tomlinson, B ;
Critchley, JAJH .
CLINICAL AUTONOMIC RESEARCH, 1997, 7 (02) :97-101
[10]
Abdominal surgery alters the calibration of bioimpedance cardiac output measurement [J].
Critchley, LAH ;
Leung, DHY ;
Short, TG .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1996, 13 (01) :1-8