Impedance cardiography - The impact of new technology

被引:38
作者
Critchley, LAH [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Hong Kong, Peoples R China
关键词
measurement techniques; impedance cardiography;
D O I
10.1046/j.1365-2044.1998.437-az0550.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The 1990s have witnessed major advances in impedance cardiography technology. Problems existed with the methods used to calculate cardiac output. Excessive lung fluid, as often found in critically ill patients, may also invalidate measurements. The signal processing and measurement techniques used in older systems were deficient. The newer systems, of which there are at least six, incorporate novel and improved signal processing techniques. They also offer analog visual displays, personal computer interfacing, sophisticated analytical software and haemodynamic patient management systems. Evaluation of these systems is difficult because no true 'gold standard' method of cardiac output measurement exists. When compared with thermodilution techniques, limits of agreement of +/- 20-30% seem acceptable. These Limits can be achieved in normal subjects but not in critically ill patients. Validation data are available for only half of the new systems. Until. recently, the main application for impedance cardiography has been research but improved accuracy should lead to increased clinical usage.
引用
收藏
页码:677 / 684
页数:8
相关论文
共 46 条
[1]  
ALDRETE JA, 1995, J CLIN MONITOR, V1, P131
[2]   CARDIAC-OUTPUT MEASUREMENT - LACK OF AGREEMENT BETWEEN THERMODILUTION AND THORACIC ELECTRIC BIOIMPEDANCE IN 2 CLINICAL SETTINGS [J].
ATALLAH, MM ;
DEMAIN, AD .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) :182-185
[3]   ESOPHAGEAL ELECTRODES ALLOW PRECISE ASSESSMENT OF CARDIAC-OUTPUT BY BIOIMPEDANCE [J].
BALESTRA, B ;
MALACRIDA, R ;
LEONARDI, L ;
SUTER, P ;
MARONE, C .
CRITICAL CARE MEDICINE, 1992, 20 (01) :62-67
[4]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   DETERMINATION OF CARDIAC-OUTPUT DURING POSITIVE ENDEXPIRATORY PRESSURE - NONINVASIVE ELECTRICAL BIOIMPEDANCE COMPARED WITH STANDARD THERMODILUTION [J].
CASTOR, G ;
MOLTER, G ;
HELMS, J ;
NIEDERMARK, I ;
ALTMAYER, P .
CRITICAL CARE MEDICINE, 1990, 18 (05) :544-546
[7]   SIMULTANEOUS MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION, THORACIC ELECTRICAL BIOIMPEDANCE AND DOPPLER ULTRASOUND [J].
CASTOR, G ;
KLOCKE, RK ;
STOLL, M ;
HELMS, J ;
NIEDERMARK, I .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) :133-138
[8]  
CRITCHLEY LA, 1994, BRIT J ANAESTH, V72, P464
[9]   Non-invasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man [J].
Critchley, LAH ;
Conway, F ;
Anderson, PJ ;
Tomlinson, B ;
Critchley, JAJH .
CLINICAL AUTONOMIC RESEARCH, 1997, 7 (02) :97-101
[10]   Abdominal surgery alters the calibration of bioimpedance cardiac output measurement [J].
Critchley, LAH ;
Leung, DHY ;
Short, TG .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1996, 13 (01) :1-8